Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 446-449, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Medcalf, E. A.
Right arrow Articles by Price, C. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Medcalf, E. A.
Right arrow Articles by Price, C. P.

Clinical Chemistry, Vol 36, 446-449, Copyright © 1990 by American Association for Clinical Chemistry

Rapid, robust method for measuring low concentrations of albumin in urine

EA Medcalf, DJ Newman, EG Gorman and CP Price
Department of Clinical Biochemistry, London Hospital Medical College, U.K.

We describe a rapid particle-enhanced turbidimetric immunoassay for albumin in urine. Intra- and interassay CVs were less than 5% and less than 10%, respectively, the detection limit is 2 mg/L, and the working range extends to 200 mg/L. Mean analytical recovery of albumin added to centrifuged urines was 100% (SD 10.6%), and, when results were compared with those by the Pharmacia RIA, the correlation coefficient was 0.99. The working reagents are stable for at least six months; thus this assay is suited for both batch and urgent analysis.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
H. Wang, Y. Zhang, B. Yan, L. Liu, S. Wang, G. Shen, and R. Yu
Rapid, Simple, and Sensitive Immunoagglutination Assay with SiO2 Particles and Quartz Crystal Microbalance for Quantifying Schistosoma japonicum Antibodies
Clin. Chem., November 1, 2006; 52(11): 2065 - 2071.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Holownia, E. Bishop, D. J. Newman, W. G. John, and C. P. Price
Adaptation of latex-enhanced assay for percent glycohemoglobin to a Dade Dimension(R) analyzer
Clin. Chem., January 1, 1997; 43(1): 76 - 84.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
H. Thakkar, D. J. Newman, P. Holownia, C. L. Davey, C.-C. Wang, J. Lloyd, A. R. Craig, and C. P. Price
Development and validation of a particle-enhanced turbidimetric inhibition assay for urine albumin on the Dade aca(R) analyzer
Clin. Chem., January 1, 1997; 43(1): 109 - 113.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.