Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 466-469, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rouilly, M.
Right arrow Articles by Simon, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rouilly, M.
Right arrow Articles by Simon, W.

Clinical Chemistry, Vol 36, 466-469, Copyright © 1990 by American Association for Clinical Chemistry

Neutral ionophore-based selective electrode for assaying the activity of magnesium in undiluted blood serum

M Rouilly, B Rusterholz, UE Spichiger and W Simon
Department of Organic Chemistry, Swiss Federal Institute of Technology, Zurich, Switzerland.

The concentration of free, ionized magnesium in undiluted blood serum can be determined potentiometrically with a new magnesium-selective carrier in polymeric membrane electrodes (by weight 66% plasticizer, approximately 33% polyvinyl chloride and approximately 1% ionophore). However, discrimination of calcium by the new ionophore-added membrane is not sufficient to keep calcium interference to less than 1%. To correct for the interference by calcium, we determine the calcium activity of the serum sample with a calcium-selective electrode and calibrate the magnesium-selective electrode with standard solutions containing calcium in the concentrations found. In this way we determined the free ionized magnesium in five plasma samples from five different persons and found it to be within the range expected for magnesium in undiluted serum.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
L. M. Thienpont, K. Dewitte, and D. Stockl
Serum complexed magnesium--a cautionary note on its estimation and its relevance for standardizing serum ionized magnesium.
Clin. Chem., January 1, 1999; 45(1): 154 - 155.
[Full Text]


Home page
Clin. Chem.Home page
H. J. Huijgen, R. Sanders, R. W. van Olden, M. G. Klous, F. R. Gaffar, and G. T. B. Sanders
Intracellular and extracellular blood magnesium fractions in hemodialysis patients; is the ionized fraction a measure of magnesium excess?
Clin. Chem., March 1, 1998; 44(3): 639 - 648.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
N. N. Rehak, S. A. Cecco, J. E. Niemela, and R. J. Elin
Thiocyanate in smokers interferes with the Nova magnesium ion-selective electrode
Clin. Chem., September 1, 1997; 43(9): 1595 - 1600.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.