Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 503-508, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kahan, I.
Right arrow Articles by Diamandis, E. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kahan, I.
Right arrow Articles by Diamandis, E. P.

Clinical Chemistry, Vol 36, 503-508, Copyright © 1990 by American Association for Clinical Chemistry

Sensitive time-resolved fluorescence immunoassay of somatotropin in serum

I Kahan, A Papanastasiou-Diamandi, G Ellis, SK Makela, J McLaurin, M D'Costa and EP Diamandis
CyberFluor Inc., Toronto, Canada.

We describe a new "sandwich"-type non-isotopic immunoassay for human somatotropin (GH, growth hormone) in serum. In the assay, GH is captured by a monoclonal antibody immobilized in a white microtiter well and simultaneously reacted with a second biotinylated monoclonal antibody. The degree of binding of biotinylated antibody, which increases with increasing amount of GH in the sample, is quantified by adding streptavidin labeled with the europium chelate of 4.7 - bis(chlorosulfophenyl) - 1.10 - phenanthroline - 2.9 - dicarboxylic acid. The fluorescent complex on the solid phase is then measured by excitation at 337.1 nm (nitrogen laser) and monitoring the emission at 615 nm in a gated fluorometer/analyzer. The proposed procedure has short incubation times (less than 4 h protocol), uses only 25 microL of serum per microtiter well, and gives precise and accurate results. The method was clinically evaluated with samples obtained from pediatric patients undergoing investigation for growth abnormalities and from a patient with acromegaly.


The following articles in journals at HighWire Press have cited this article:


Home page
CVIHome page
A. H. Peruski and L. F. Peruski Jr.