Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 723-727, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Abendschein, D. R.
Right arrow Articles by Nohara, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Abendschein, D. R.
Right arrow Articles by Nohara, R.

Clinical Chemistry, Vol 36, 723-727, Copyright © 1990 by American Association for Clinical Chemistry

Optimized preservation of isoforms of creatine kinase MM isoenzyme in plasma specimens and their rapid quantification by semi-automated chromatofocusing

DR Abendschein, HL Fontanet and R Nohara
Cardiovascular Division, Washington University School of Medicine, St. Louis, MO 63110.

We report a convenient chromatofocusing procedure for rapid and sensitive quantification of isoforms of the MM isoenzyme of creatine kinase (EC 2.7.3.2) in plasma and efficient methods for preserving isoform profiles during handling of specimens. The assay involves use of prepacked, re-usable Mono P chromatofocusing columns and a "Fast Protein Liquid Chromatograph" (FPLC) system with on-line detection of isoform enzymatic activity in column effluent. Profiles of isoforms are analyzed within 25 min with the use of a 1-mL column; the lower limit of sensitivity for CK activity is 5 mU, and recovery of each isoform is within 1% of the amount added to plasma. Collection of blood specimens in Vacutainer Tubes containing 28.5 mumol of EDTA (final concentration in plasma, 7 to 10 mmol/L) inhibited carboxypeptidase activity in plasma by 76%, sufficient to essentially abolish isoform conversion in vitro at room temperature. These methods should facilitate applications of isoform analysis for diagnosis of myocardial infarction and coronary artery recanalization.


The following articles in journals at HighWire Press have cited this article:


Home page
CirculationHome page
T. Laperche, P. G. Steg, M. Dehoux, J. Benessiano, G. Grollier, E. Aliot, J.-M. Mossard, P. Aubry, D. Coisne, M. Hanssen, et al.
A Study of Biochemical Markers of Reperfusion Early After Thrombolysis for Acute Myocardial Infarction
Circulation, October 15, 1995; 92(8): 2079 - 2086.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.