Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 900-903, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Keinanen, M.
Right arrow Articles by Kovanen, P. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Keinanen, M.
Right arrow Articles by Kovanen, P. T.

Clinical Chemistry, Vol 36, 900-903, Copyright © 1990 by American Association for Clinical Chemistry

Use of polymerase chain reaction to detect heterozygous familial hypercholesterolemia

M Keinanen, JP Ojala, E Helve, K Aalto-Setala, K Kontula and PT Kovanen
Department of Medical Genetics, University of Helsinki, Finland.

We used a modification of the polymerase chain reaction (PCR), involving two pairs of oligonucleotide primers, to detect a mutation in the low-density lipoprotein (LDL) receptor gene, commonly occurring among patients with familial hypercholesterolemia (FH) in Finland. This mutation, called FH-Helsinki, involves a large (about 9500 base pairs, bp) deletion in the LDL receptor gene extending from intron 15 to exon 18. For the PCR, one pair of primers was designed to cover both sides of the deletion in its immediate vicinity. In the presence of the deletion, the primers were brought close enough to each other to allow the amplification and electrophoretic detection of a 300-bp amplification product. In the absence of the deletion, no amplification occurred and this band accordingly was not visible in the gel. To render the interpretation of the results unequivocal, we designed a second pair of oligonucleotide primers. This pair of primers allowed another amplification product (158 bp) to appear in samples containing a normal exon 17, i.e., in DNA specimens from healthy subjects and FH heterozygotes with or without the FH-Helsinki deletion. The technique is easy to perform, avoids the use of radioactive reagents, and is applicable to the detection of any extensive DNA deletion.