Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 1288-1294, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zaidi, M.
Right arrow Articles by Self, C. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zaidi, M.
Right arrow Articles by Self, C. H.

Clinical Chemistry, Vol 36, 1288-1294, Copyright © 1990 by American Association for Clinical Chemistry

Development and performance of a highly sensitive and specific two-site immunometric assay of calcitonin gene-related peptide

M Zaidi, R Seth, SI Girgis and CH Self
Department of Cellular and Molecular Sciences, St. George's Hospital Medical School, Tooting, London, U.K.

Calcitonin gene-related peptide (CGRP), a potent endogenous circulating vasodilator, is produced by the alternative splicing of the calcitonin/CGRP gene and is expressed mainly in neural and cardiovascular tissues. We recently reported a highly sensitive radioimmunoassay of CGRP, based on an antiserum recognizing the C- terminus of the molecule. We have also found that circulating immunoreactive CGRP is heterogeneous; thus we are unable to measure selectively the intact molecule with our one-site competitive approach. We therefore attempted to construct a two-site immunometric assay involving two antibodies, one that detects the C-terminus and another that recognizes the midregion of the molecule. To enhance assay sensitivity, we applied a colorimetric amplification system to this assay. This rapid, robust, and reproducible assay provides more nearly accurate estimates of circulating CGRP and offers a sensitive and more specific alternative to the radioimmunoassay, with advantages in speed, simplicity, and convenience.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.