Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 1305-1311, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Munkvad, S.
Right arrow Articles by Gram, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Munkvad, S.
Right arrow Articles by Gram, J.

Clinical Chemistry, Vol 36, 1305-1311, Copyright © 1990 by American Association for Clinical Chemistry

Specific, sensitive, precise, and rapid functional chromogenic assay of activated first complement component (C1) in plasma

S Munkvad, J Jespersen, J Sidelmann and J Gram
Department of Clinical Chemistry, Ribe County Hospital, Esbjerg, Denmark.

We present a new functional assay for the first complement component (C1) in plasma, based on its activation by inhibition of the C1- esterase inhibitor (C1-inh) when monospecific antiserum to C1-inh is added to the plasma. After maximal activation, we can determine the concentration of activated C1 by using an amidolytic rate assay with a chromogenic substrate. We have optimized the assay conditions with respect to incubation time, concentration of antiserum to C1-inh, ionic strength, and pH. Our method determines specifically the concentration in plasma of free activated C1, not complexes of activated C1 with C1- inh, and is not influenced by the concentration of C1-inh in the test sample. Concentrations of C1 correlated significantly with activities determined by a hemolytic assay (r = 0.55, t = 4.09, P less than 0.001). The estimated interassay CV was 5% and the intra-assay CV was 1%. The sensitivity, imprecision, and practical test performance of our assay are superior to those of conventionally used hemolytic assays.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.