Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 1364-1368, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Slazyk, W. E.
Right arrow Articles by Spierto, F. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Slazyk, W. E.
Right arrow Articles by Spierto, F. W.

Clinical Chemistry, Vol 36, 1364-1368, Copyright © 1990 by American Association for Clinical Chemistry

Liquid-chromatographic measurement of biopterin and neopterin in serum and urine

WE Slazyk and FW Spierto
Centers for Disease Control, U.S. Department of Health and Human Services, Atlanta, GA 30333.

We report an improved "high-performance" liquid-chromatographic (HPLC) method for measuring biopterin and neopterin in serum and urine. Specimens are acidified, treated with iodine in 0.2 mol/L trichloroacetic acid, party purified on Bio-Rad MP-50 cation-exchange columns, and analyzed by reversed-phase HPLC with fluorometric detection. The minimal concentration of biopterin detectable is 0.3 micrograms/L in a 50-microL injection. The total CV is less than or equal to 10%. Improvements over other reported methods include the use of a single, simplified sample-preparation step with a Baker-10 SPE System, and a guard column to increase analytical column stability and analyte recovery. The assay is semiautomated to reduce technician time and improve precision. Mean observed values for biopterin and neopterin in sera of normal human adults were 1.64 and 5.52 micrograms/L, respectively. The mean ratio of neopterin to biopterin in acidified adult urine samples was lower than that found in matched nonacidified samples (n = 10). Serum specimens from diagnosed phenylketonuric (PKU) and hyperphenylalaninemic patients were also analyzed for biopterin and neopterin; the findings agreed with reported values for similar patients. One patient, previously identified as an atypical PKU patient, showed serum values of neopterin and biopterin suggestive of a defect in biopterin synthesis.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.