Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 1573-1580, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fogt, E. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fogt, E. J.

Clinical Chemistry, Vol 36, 1573-1580, Copyright © 1990 by American Association for Clinical Chemistry

Continuous ex vivo and in vivo monitoring with chemical sensors

EJ Fogt
Medtronic Inc., Brooklyn Center, MN 55430.

The chemical species of principal clinical interest for continuous monitoring include oxygen, carbon dioxide, pH, potassium, and glucose. Although sensors exist for all of these analytes, relatively few continuous monitors are used for blood chemistries. Reviewing the available electrochemical and optical approaches along with the expected system performance requirements provides some insight into the reasons for this. In particular, the performance of sensor systems is significantly dependent on the environment in which they are used: transcutaneous, intravascular, intramuscular, etc. The future success and acceptance of "real-time" continuous monitoring of the critically ill patient probably does not require the development of new sensors for additional species. Rather, improvements in the stability of existing devices and protection of the sensor's chemistry from the environment are needed. Eventually, the development of new sensing technologies, e.g., near infrared spectroscopy, may lead to a completely noninvasive system capable of monitoring a broad spectrum of analytes.


The following articles in journals at HighWire Press have cited this article:


Home page
Anesth. Analg.Home page
P. Eberhard
The Design, Use, and Results of Transcutaneous Carbon Dioxide Analysis: Current and Future Directions
Anesth. Analg., December 1, 2007; 105(6S_Suppl): S48 - S52.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
F. M. Musteata, M. L. Musteata, and J. Pawliszyn
Fast In Vivo Microextraction: A New Tool for Clinical Analysis
Clin. Chem., April 1, 2006; 52(4): 708 - 715.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.