Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 1646-1649, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gourmelin, Y.
Right arrow Articles by Truchaud, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gourmelin, Y.
Right arrow Articles by Truchaud, A.

Clinical Chemistry, Vol 36, 1646-1649, Copyright © 1990 by American Association for Clinical Chemistry

Electrode measurement of glucose and urea in undiluted samples

Y Gourmelin, B Gouget and A Truchaud
Biochemistry Laboratory, Meaux Hospital, France.

The development of ion-selective electrodes (ISEs) for electrolyte measurements necessitates a re-evaluation of the biological and clinical interpretation of a result. In pathological situations (e.g., hyperlipidemia and hyperproteinemia) direct potentiometry is the method of choice for ion measurements in blood. However, the "plasma water effect" exists also in normal samples, requiring new reference values for physiological ranges. A compromise between medical and instrumentation workers retained the old reference values (flame photometry for Na+ and K+) by introducing correction factors into the ISE instruments, so that the results for direct ISE and flame photometry are the same for "normal" samples. Analyses of "abnormal" samples will reveal biases between the two methods. Now, a new generation of electrodes for assaying additional metabolites reopens the issue. Although classical methods measure a quantity of substance in a predetermined volume of sample, the majority of the substance is usually in the aqueous phase, and the volumes occupied by lipid and protein are not taken into consideration. In evaluating the NOVA 12 instrument (NOVA Biomedical), using electrodes for direct measurement in serum or plasma of Na, K, Cl, total CO2, urea, and glucose, we have demonstrated the inadequacy of classical measurements of urea and glucose, especially in pathological situations characterized by a large variation in the plasma water fraction.


The following articles in journals at HighWire Press have cited this article:


Home page
J DAIRY SCIHome page
S. K. Bhandari, K. H. Ominski, K. M. Wittenberg, and J. C. Plaizier
Effects of Chop Length of Alfalfa and Corn Silage on Milk Production and Rumen Fermentation of Dairy Cows
J Dairy Sci, May 1, 2007; 90(5): 2355 - 2366.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.