Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 1667-1672, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gonzalez, R. R.
Right arrow Articles by Vihko, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gonzalez, R. R.
Right arrow Articles by Vihko, R.

Clinical Chemistry, Vol 36, 1667-1672, Copyright © 1990 by American Association for Clinical Chemistry

Direct solid-phase time-resolved fluoroimmunoassay of 17 alpha- hydroxyprogesterone in serum and dried blood spots on filter paper

RR Gonzalez, O Maentausta, J Solyom and R Vihko
Department of Clinical Chemistry, University of Oulu, Finland.

We describe a direct, solid-phase time-resolved fluoroimmunoassay (TRFIA) for measuring 17 alpha-hydroxyprogesterone (17OHP) in serum and blood spots on filter paper. We used 17OHP-3-carboxymethyloxime (17OHP3CMO) coupled to polylysine as the label, which enabled incorporation of up to 34 atoms of europium per molecule of 17OHP, for a very high specific activity. The assay is based on competition between labeled 17OHP3CMO and 17OHP in blood specimens for polyclonal rabbit anti-17OHP antibodies. The antibody-label complex is separated by binding to anti-rabbit antibodies coated onto microtiter strips. The assay buffer contains danazol to displace 17OHP from steroid-binding proteins in serum. For serum samples, the assay is accomplished in 1 h of incubation at room temperature. The blood spot assay with filter paper discs involves incubation overnight at 4 degrees C. Results for both types of specimens from the same subjects correlated well. The lowest measurable concentrations of 17OHP (nmol/L) were 0.10 (3 SD) and 0.75 (3 SD) for serum and dried blood on filter paper, respectively. Intra- and interassay CVs were about 5-15% for both types of samples.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Association for Clinical Chemistry.