Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 36: 1675-1678, 1990;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Delanghe, J. R.
Right arrow Articles by Vanderschueren, S. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Delanghe, J. R.
Right arrow Articles by Vanderschueren, S. C.

Clinical Chemistry, Vol 36, 1675-1678, Copyright © 1990 by American Association for Clinical Chemistry

Quantitative nephelometric assay for determining myoglobin evaluated

JR Delanghe, JP Chapelle and SC Vanderschueren
Department of Clinical Chemistry, Universitair Ziekenhuis De Pintelaan, Gent, Belgium.

A recently introduced automated nephelometric immunoassay involving shell/core particles for determination of myoglobin (Behringwerke) was evaluated with the BNA Nephelometer. Method precision was good: the intra-assay CV varied between 1.5% and 6.1%; with daily calibration, the interassay CV ranged between 1.5% and 7.5%. For usual sample dilutions, the assay response varied linearly with myoglobin concentrations up to 23.1 nmol/L. After automatic dilution by the instrument, concentrations up to 2310 nmol/L could be measured without high-dose "hook" effect. Further manual dilution allowed measurement of myoglobin concentrations up to 26,000 nmol/L. Calibration was stable for at least seven days. We detected no significant interferences from hemoglobin, haptoglobin, bilirubin, iodine-containing contrast media, and rheumatoid factors. Treating lipemic samples with Lipoclean (Behringwerke) decreased test results. Simultaneously drawn serum and plasma samples from the same subject showed no consistent differences in myoglobin concentrations. The mean reference myoglobin concentration was 1.380 (SD 0.82) nmol/L for men and 0.878 (SD 0.45) nmol/L for women. In patients with renal insufficiency, serum creatinine values were moderately related to serum myoglobin values (r = 0.465). Although a commercial radioimmunoassay (Byk-Sangtec) and the nephelometric assay intercorrelated well (r = 0.929), values obtained by nephelometry were significantly lower (P less than 0.05). By both assays, results for heart and skeletal muscle tissue extracts showed no correlation, a finding that suggests the existence of multiple forms of myoglobin in human tissues. We conclude that immunonephelometry is a rapid, practical, and reliable method for measuring myoglobin in serum.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. S. Negi and A. K. Sood
Electric Field-Enhanced Sensitivity of Grafted Ligands and Receptors
Clin. Chem., February 1, 2008; 54(2): 366 - 370.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. J. Gunst, M. R. Langlois, J. R. Delanghe, M. L. De Buyzere, and G. G. Leroux-Roels
Serum creatine kinase activity is not a reliable marker for muscle damage in conditions associated with low extracellular glutathione concentration
Clin. Chem., May 1, 1998; 44(5): 939 - 943.