Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 37: 1669-1675, 1991;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Linnet, K.
Right arrow Articles by Bruunshuus, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Linnet, K.
Right arrow Articles by Bruunshuus, I.

Clinical Chemistry, Vol 37, 1669-1675, Copyright © 1991 by American Association for Clinical Chemistry

HPLC with enzymatic detection as a candidate reference method for serum creatinine

K Linnet and I Bruunshuus
Department of Clinical Chemistry, Rigshospitalet, University Hospital, Copenhagen, Denmark.

We present a candidate Reference Method for determining the concentration of serum creatinine. The method is based on HPLC combined with enzymatic determination. Creatinine plus 14[C]creatinine is extracted by cation-exchange chromatography, subjected to reversed- phase HPLC, and finally quantified enzymatically. Enzymatic measurement ensures no interference from co-eluting compounds, which has been a problem for some reported HPLC assays relying on ultraviolet detection. The average corrected recovery was 100.1% (SEM = 1.1%; n = 15). The accuracy was verified by assaying five sera with target values determined by isotope dilution mass spectrometry. The total interassay CV was less than or equal to 2.5%. We applied the method to study the specificity of HPLC-ultraviolet detection, using 72 plasma samples from hospitalized patients; no interference was noted. Thus, HPLC- ultraviolet detection appears to be specific, provided that sample cleanup is based on cation-exchange chromatography. Our diode-array detector studies of peak homogeneity supported this conclusion. Still, combined HPLC-enzymatic determination ensures even greater accuracy, ranking close to that by isotope dilution mass spectrometry.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
G. L. Myers, W. G. Miller, J. Coresh, J. Fleming, N. Greenberg, T. Greene, T. Hostetter, A. S. Levey, M. Panteghini, M. Welch, et al.
Recommendations for Improving Serum Creatinine Measurement: A Report from the Laboratory Working Group of the National Kidney Disease Education Program
Clin. Chem., January 1, 2006; 52(1): 5 - 18.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. G. Altman and J. M. Bland
Commentary on Quantifying Agreement between Two Methods of Measurement
Clin. Chem., May 1, 2002; 48(5): 801 - 802.
[Full Text] [PDF]


Home page
Stat Methods Med ResHome page
J M. Bland and D. G Altman
Measuring agreement in method comparison studies
Statistical Methods in Medical Research, April 1, 1999; 8(2): 135 - 160.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Association for Clinical Chemistry.