|
|
||||||||
Clinical Chemistry, Vol 37, 1725-1729, Copyright © 1991 by American Association for Clinical Chemistry
RR Little, HM Wiedmeyer, JD England, HK Naito and DE Goldstein
Department of Pathology, University of Missouri School of Medicine, Columbia 65212.
We describe recent changes in the College of American Pathologists Glycohemoglobin (gHb) Survey, made to improve the assessment of interlaboratory variability and the accuracy of results reported. The questionnaire portion of the survey was revised to include an updated list of current methods, and results for survey specimens were grouped according to the component measured (Hb A1, Hb A1c, or total gHb). The survey specimen material was changed to a material thought to give more reliable results with all available methods. After these changes, instituted in 1989, between-laboratory CVs decreased for some methods. Furthermore, gHb values between method types were more consistent with results obtained from fresh blood samples under very controlled laboratory conditions. However, these recent data also show that the interlaboratory variability is still quite high for some methods and that the variability within and between method types is still very great. We describe a pilot standardization program for gHb measurement.
The following articles in journals at HighWire Press have cited this article:
![]() |
C. Wilson, S. Gilliland, T. Cullen, K. Moore, Y. Roubideaux, L. Valdez, W. Vanderwagen, and K. Acton Diabetes Outcomes in the Indian Health System During the Era of the Special Diabetes Program for Indians and the Government Performance and Results Act Am J Public Health, September 1, 2005; 95(9): 1518 - 1522. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. E. Goldstein, R. R. Little, R. A. Lorenz, J. I. Malone, D. Nathan, C. M. Peterson, and D. B. Sacks Tests of Glycemia in Diabetes Diabetes Care, July 1, 2004; 27(7): 1761 - 1773. [Full Text] [PDF] |
||||
![]() |
W. Hoelzel, C. Weykamp, J.-O. Jeppsson, K. Miedema, J. R. Barr, I. Goodall, T. Hoshino, W. G. John, U. Kobold, R. Little, et al. IFCC Reference System for Measurement of Hemoglobin A1c in Human Blood and the National Standardization Schemes in the United States, Japan, and Sweden: A Method-Comparison Study Clin. Chem., January 1, 2004; 50(1): 166 - 174. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S. Gilliland, J. S. Carter, B. Skipper, and K. J. Acton HbA1c Levels Among American Indian/Alaska Native Adults Diabetes Care, December 1, 2002; 25(12): 2178 - 2183. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. L. Norris, J. Lau, S. J. Smith, C. H. Schmid, and M. M. Engelgau Self-Management Education for Adults With Type 2 Diabetes: A meta-analysis of the effect on glycemic control Diabetes Care, July 1, 2002; 25(7): 1159 - 1171. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. R. Little, C. L. Rohlfing, H.-M. Wiedmeyer, G. L. Myers, D. B. Sacks, and D. E. Goldstein The National Glycohemoglobin Standardization Program: A Five-Year Progress Report Clin. Chem., November 1, 2001; 47(11): 1985 - 1992. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Acton, R. Shields, S. Rith-Najarian, B. Tolbert, J. Kelly, K. Moore, L. Valdez, B. Skipper, and D. Gohdes Applying the Diabetes Quality Improvement Project Indicators in the Indian Health Service Primary Care Setting Diabetes Care, January 1, 2001; 24(1): 22 - 26. [Abstract] [Full Text] |
||||
![]() |
S. C. Wong and T. C. Aw Hb E1c as an Indicator for the Presence of Hb AE Phenotype in Diabetic Patients Clin. Chem., March 1, 1998; 44(3): 660 - 662. [Full Text] [PDF] |
||||
![]() |
D. Gohdes, S. Rith-Najarian, K. Acton, and R. Shields Improving Diabetes Care in the Primary Health Setting: The Indian Health Service Experience Ann Intern Med, January 1, 1996; 124(1_Part_2): 149 - 152. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |