Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 37: 1922-1926, 1991;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jones, R. G.
Right arrow Articles by Whicher, J. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jones, R. G.
Right arrow Articles by Whicher, J. T.

Clinical Chemistry, Vol 37, 1922-1926, Copyright © 1991 by American Association for Clinical Chemistry

Use of immunoglobulin heavy-chain and light-chain measurements in a multicenter trial to investigate monoclonal components: II. Classification by use of computer-based algorithms

RG Jones, F Aguzzi, J Bienvenu, C Gasparro, MR Bergami, P Bianchi, A Perinet, G Penn, I Keller and JT Whicher
Department of Chemical Pathology and Immunology, University of Leeds, U.K.

We describe a computer algorithm for classifying serum monoclonal proteins (MC) based on serum protein electrophoresis (SPE) and the automated measurement of kappa and lambda light chains and IgG, IgA, and IgM. We developed the algorithm by using a large database of unselected samples containing MC collected in a multicenter study. The performance of the algorithm was optimized by using iterative computational procedures and was tested on both the development database and on an independent set of MC-containing samples. With the development database, the algorithm correctly classified 50% and misassigned 2.5% of the MC. Where the MC were present in concentrations greater than 10 g/L, the rate of successful classification increased to 72% with 3% misclassification. When the algorithm was tested on a group of 101 MC-containing samples from an independent source, 67% were correctly classified and 8% misclassified, half of the latter being unusual IgD myelomas. We discuss the scope for the application of the algorithm in routine laboratory practice involving personal computer software.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Association for Clinical Chemistry.