Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 37: 1938-1944, 1991;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Westgard, J. O.
Right arrow Articles by Wiebe, D. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Westgard, J. O.
Right arrow Articles by Wiebe, D. A.

Clinical Chemistry, Vol 37, 1938-1944, Copyright © 1991 by American Association for Clinical Chemistry

Cholesterol operational process specifications for assuring the quality required by CLIA proficiency testing

JO Westgard and DA Wiebe
Department of Pathology and Laboratory Medicine, Medical School, University of Wisconsin, Madison 53792.

Current U.S. governmental regulations and requirements for the quality of laboratory tests do not provide a consistent form, comparable numbers, or practical specifications for the routine operation of laboratory testing processes. For cholesterol, as an example, the Health Care Financing Administration provides an analytical performance criterion for proficiency testing to enforce the Clinical Laboratory Improvement Act (CLIA), whereas the U.S. National Cholesterol Education Program (NCEP) provides clinical guidelines for test interpretation, as well as analytical goals for imprecision and inaccuracy. Routine operating process specifications for imprecision, inaccuracy, and quality control can be derived from the analytical and clinical requirements for quality. Use of an analytical "total error" model and a clinical "decision interval" model provides logically consistent and numerically comparable specifications. Studies with these coherent models indicate that a cholesterol testing process properly planned to satisfy the CLIA analytical requirement will also satisfy the NCEP clinical requirement. To provide 90% assurance of detecting systematic shifts of a magnitude that would cause the CLIA analytical requirement to be exceeded, the operational specifications for a cholesterol testing process are an allowable CV of less than or equal to 2%, an allowable bias of less than or equal to 1%, and a control procedure with two measurements per run interpreted by 1(3)s, 1(2.5)s, or 1(3)s/2(2)s/R4s control rules.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
S. P. Caudill, S. J. Smith, G. R. Cooper, G. L. Myers, J. O. Westgard, and D. A. Wiebe
Adequacy of NCEP Recommendations for Total Cholesterol, Triglycerides, HDLC, and LDLC Measurements Two of the authors of the above- mentioned article reply:
Clin. Chem., May 1, 1998; 44(5): 1063 - 1066.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
P. C. Fallest-Strobl, E. Olafsdottir, D. A. Wiebe, and J. O. Westgard
Comparison of NCEP performance specifications for triglycerides, HDL-, and LDL-cholesterol with operating specifications based on NCEP clinical and analytical goals
Clin. Chem., November 1, 1997; 43(11): 2164 - 2168.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. O. Westgard and B. Stein
Automated Selection of Statistical Quality-Control Procedures to Assure Meeting Clinical or Analytical Quality Requirements
Clin. Chem., February 1, 1997; 43(2): 400 - 403.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Association for Clinical Chemistry.