Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 37: 2029-2037, 1991;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stibler, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stibler, H.

Clinical Chemistry, Vol 37, 2029-2037, Copyright © 1991 by American Association for Clinical Chemistry

Carbohydrate-deficient transferrin in serum: a new marker of potentially harmful alcohol consumption reviewed

H Stibler
Department of Neurology, Karolinska Hospital, Stockholm, Sweden.

During the last 16 years an increasing number of studies have indicated a new diagnostic marker of alcohol abuse, unrelated to any of the conventional markers of alcoholism. This marker, now called carbohydrate-deficient transferrin, consists mainly of one or two isoforms of transferrin that are deficient in their terminal trisaccharides. Such isoforms have so far been detected by methods based on charge, i.e., isoelectric focusing, chromatofocusing, and anion-exchange chromatography of various designs combined with immunological detection techniques. This transferrin abnormality measures an accumulated effect of alcohol consumption, appearing after regular intake of 50-80 g of ethanol/day for at least one week and normalizing slowly during abstinence (half-life = about 15 days). To summarize all studies to date, approximately 2500 individuals have been examined, with a total clinical sensitivity of 82% and a specificity of 97%. False-positive results have only occasionally been reported: in a few patients with severe liver disease, usually primary biliary cirrhosis and chronic active hepatitis; in patients with genetic D variants of transferrin; and in patients with (and some carriers of) a recently identified inborn error of glycoprotein metabolism. The mechanism behind the transferrin abnormality is unknown but an acetaldehyde-mediated inhibition of glycosyl transfer has been suggested. Carbohydrate-deficient transferrin may thus offer a new possibility of diagnosing alcohol-related disorders. Its measurement is little affected by other conditions and, contrary to conventional markers of alcohol abuse, is apparently largely independent of concomitant liver disease.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
J. B. Whitfield, V. Dy, P. A.F. Madden, A. C. Heath, N. G. Martin, and G. W. Montgomery
Measuring Carbohydrate-Deficient Transferrin by Direct Immunoassay: Factors Affecting Diagnostic Sensitivity for Excessive Alcohol Intake
Clin. Chem., July 1, 2008; 54(7): 1158 - 1165.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
J. P. Bergstrom and A. Helander
Clinical Characteristics of Carbohydrate-Deficient Transferrin (%Disialotransferrin) Measured by HPLC: Sensitivity, Specificity, Gender Effects, and Relationship with other Alcohol Biomarkers
Alcohol Alcohol., April 24, 2008; (2008) agn017v2.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. R. Delanghe, A. Helander, J. P.M. Wielders, J. M. Pekelharing, H. J. Roth, F. Schellenberg, C. Born, E. Yagmur, W. Gentzer, and H. Althaus
Development and Multicenter Evaluation of the N Latex CDT Direct Immunonephelometric Assay for Serum Carbohydrate-Deficient Transferrin
Clin. Chem., June 1, 2007; 53(6): 1115 - 1121.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
S. Wopereis, S. Grunewald, K. M.L.C. Huijben, E. Morava, R. Mollicone, B. G.M. van Engelen, D. J. Lefeber, and R. A. Wevers
Transferrin and Apolipoprotein C-III Isofocusing Are Complementary in the Diagnosis of N- and O-Glycan Biosynthesis Defects
Clin. Chem., February 1, 2007; 53(2): 180 - 187.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
J. HIETALA, H. KOIVISTO, P. ANTTILA, and O. NIEMELA
COMPARISON OF THE COMBINED MARKER GGT-CDT AND THE CONVENTIONAL LABORATORY MARKERS OF ALCOHOL ABUSE IN HEAVY DRINKERS, MODERATE DRINKERS AND ABSTAINERS
Alcohol Alcohol., September 1, 2006; 41(5): 528 - 533.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
F. Bortolotti, G. De Paoli, J. P. Pascali, M. T. Trevisan, M. Floreani, and F. Tagliaro
Analysis of Carbohydrate-Deficient Transferrin: Comparative Evaluation of Turbidimetric Immunoassay, Capillary Zone Electrophoresis, and HPLC
Clin. Chem., December 1, 2005; 51(12): 2368 - 2371.
[Full Text] [PDF]


Home page
Alcohol AlcoholHome page
M. AALTO and K. SEPPA
USE OF LABORATORY MARKERS AND THE AUDIT QUESTIONNAIRE BY PRIMARY CARE PHYSICIANS TO DETECT ALCOHOL ABUSE BY PATIENTS
Alcohol Alcohol., November 1, 2005; 40(6): 520 - 523.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
B. M.R. Appenzeller and R. Wennig
Altered Distribution of Transferrin Isoforms According to Serum Storage Conditions
Clin. Chem., November 1, 2005; 51(11): 2159 - 2162.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Helander, J. P.M. Wielders, R. te Stroet, and J. P. Bergstrom
Comparison of HPLC and Capillary Electrophoresis for Confirmatory Testing of the Alcohol Misuse Marker Carbohydrate-Deficient Transferrin
Clin. Chem., August 1, 2005; 51(8): 1528 - 1531.
[Full Text] [PDF]


Home page
Alcohol AlcoholHome page
M. J. EMMEN, G. M. SCHIPPERS, H. WOLLERSHEIM, and G. BLEIJENBERG
ADDING PSYCHOLOGIST'S INTERVENTION TO PHYSICIANS' ADVICE TO PROBLEM DRINKERS IN THE OUTPATIENT CLINIC
Alcohol Alcohol., May 1, 2005; 40(3): 219 - 226.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Van Campenhout, C. Van Campenhout, A. R. Lagrou, and B. Manuel-y-Keenoy
Effects of in Vitro Glycation on Fe3+ Binding and Fe3+ Isoforms of Transferrin
Clin. Chem., September 1, 2004; 50(9): 1640 - 1649.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
H. Koch, G.-J. Meerkerk, J. O. M. Zaat, M. F. Ham, R. J. P. M. Scholten, and W. J. J. Assendelft
ACCURACY OF CARBOHYDRATE-DEFICIENT TRANSFERRIN IN THE DETECTION OF EXCESSIVE ALCOHOL CONSUMPTION: A SYSTEMATIC REVIEW
Alcohol Alcohol., March 1, 2004; 39(2): 75 - 85.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
P. Anttila, K. Jarvi, J. Latvala, and O. Niemela
METHOD-DEPENDENT CHARACTERISTICS OF CARBOHYDRATE-DEFICIENT TRANSFERRIN MEASUREMENTS IN THE FOLLOW-UP OF ALCOHOLICS
Alcohol Alcohol., January 1, 2004; 39(1): 59 - 63.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
S. Wopereis, S. Grunewald, E. Morava, J. M. Penzien, P. Briones, M. T. Garcia-Silva, P. N.M. Demacker, K. M.L.C. Huijben, and R. A. Wevers
Apolipoprotein C-III Isofocusing in the Diagnosis of Genetic Defects in O-Glycan Biosynthesis
Clin. Chem., November 1, 2003; 49(11): 1839 - 1845.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
B. Ramdani, V. Nuyens, T. Codden, G. Perpete, J. Colicis, A. Lenaerts, J.-P. Henry, and F. J. Legros
Analyte Comigrating with Trisialotransferrin during Capillary Zone Electrophoresis of Sera from Patients with Cancer
Clin. Chem., November 1, 2003; 49(11): 1854 - 1864.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Helander, A. Husa, and J.-O. Jeppsson
Improved HPLC Method for Carbohydrate-deficient Transferrin in Serum
Clin. Chem., November 1, 2003; 49(11): 1881 - 1890.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
P. Anttila, K. Jarvi, J. Latvala, J. E. Blake, and O. Niemela
DIAGNOSTIC CHARACTERISTICS OF DIFFERENT CARBOHYDRATE-DEFICIENT TRANSFERRIN METHODS IN THE DETECTION OF PROBLEM DRINKING: EFFECTS OF LIVER DISEASE AND ALCOHOL CONSUMPTION
Alcohol Alcohol., September 1, 2003; 38(5): 415 - 420.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
T. Sarkola, H. Dahl, C. J. P. Eriksson, and A. Helander
URINARY ETHYL GLUCURONIDE AND 5-HYDROXYTRYPTOPHOL LEVELS DURING REPEATED ETHANOL INGESTION IN HEALTHY HUMAN SUBJECTS
Alcohol Alcohol., July 1, 2003; 38(4): 347 - 351.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
T. Arndt
Asialotransferrin--An Alternative to Carbohydrate-deficient Transferrin?
Clin. Chem., June 1, 2003; 49(6): 1022 - 1023.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
F. J. Legros, V. Nuyens, M. Baudoux, K. Zouaoui Boudjeltia, J.-L. Ruelle, J. Colicis, F. Cantraine, and J.-P. Henry
Use of Capillary Zone Electrophoresis for Differentiating Excessive from Moderate Alcohol Consumption
Clin. Chem., March 1, 2003; 49(3): 440 - 449.
[Abstract] [Full Text] [PDF]


Home page
Biol Res NursHome page
M. S. Sommers, C. Savage, J. Wray, and J. M. Dyehouse
Laboratory Measures of Alcohol (Ethanol) Consumption: Strategies to Assess Drinking Patterns with Biochemical Measures
Biol Res Nurs, January 1, 2003; 4(3): 203 - 217.
[Abstract] [PDF]


Home page
Clin. Chem.Home page
F. J. Legros, V. Nuyens, E. Minet, P. Emonts, K. Z. Boudjeltia, A. Courbe, J.-L. Ruelle, J. Colicis, F. de L'Escaille, and J.-P. Henry
Carbohydrate-deficient Transferrin Isoforms Measured by Capillary Zone Electrophoresis for Detection of Alcohol Abuse
Clin. Chem., December 1, 2002; 48(12): 2177 - 2186.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
T. Arndt and J. Kropf
Alcohol Abuse and Carbohydrate-deficient Transferrin Analysis: Are Screening and Confirmatory Analysis Required?
Clin. Chem., November 1, 2002; 48(11): 2072 - 2074.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
E. Arrer, C. Meco, G. Oberascher, W. Piotrowski, K. Albegger, and W. Patsch
{beta}-Trace Protein as a Marker for Cerebrospinal Fluid Rhinorrhea
Clin. Chem., June 1, 2002; 48(6): 939 - 941.
[Full Text] [PDF]


Home page
Arch Intern MedHome page
J.-B. Daeppen, P. Gache, U. Landry, E. Sekera, V. Schweizer, S. Gloor, and B. Yersin
Symptom-Triggered vs Fixed-Schedule Doses of Benzodiazepine for Alcohol Withdrawal: A Randomized Treatment Trial
Arch Intern Med, May 27, 2002; 162(10): 1117 - 1121.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
A. Helander
MULTICENTRE VALIDATION STUDY OF INSTRUMENT APPLICATIONS FOR %CDT, AN IMMUNOASSAY FOR QUANTIFICATION OF CARBOHYDRATE-DEFICIENT TRANSFERRIN IN SERUM
Alcohol Alcohol., May 1, 2002; 37(3): 209 - 212.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
T. Laatikainen, H. Alho, E. Vartiainen, P. Jousilahti, P. Sillanaukee, and P. Puska
SELF-REPORTED ALCOHOL CONSUMPTION AND ASSOCIATION TO CARBOHYDRATE-DEFICIENT TRANSFERRIN AND GAMMA-GLUTAMYLTRANSFERASE IN A RANDOM SAMPLE OF THE GENERAL POPULATION IN THE REPUBLIC OF KARELIA, RUSSIA AND IN NORTH KARELIA, FINLAND
Alcohol Alcohol., May 1, 2002; 37(3): 282 - 288.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
F. de Loos, K. M.L.C. Huijben, N. C.A.J. van der Kar, L. A.H. Monnens, L. P.W.J. van den Heuvel, J. E.M. Groener, R. A. de Moor, and R. A. Wevers
Hemolytic Uremic Syndrome Attributable to Streptococcus pneumoniae Infection: A Novel Cause for Secondary Protein N-Glycan Abnormalities
Clin. Chem., May 1, 2002; 48(5): 781 - 784.
[Full Text] [PDF]


Home page
Arch Intern MedHome page
P. Jousilahti, E. Vartiainen, H. Alho, K. Poikolainen, and P. Sillanaukee
Opposite Associations of Carbohydrate-Deficient Transferrin and {gamma}-Glutamyltransferase With Prevalent Coronary Heart Disease
Arch Intern Med, April 8, 2002; 162(7): 817 - 821.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
A. Reif, H. Keller, M. Schneider, S. Kamolz, A. Schmidtke, and A. J. Fallgatter
CARBOHYDRATE-DEFICIENT TRANSFERRIN IS ELEVATED IN CATABOLIC FEMALE PATIENTS
Alcohol Alcohol., November 1, 2001; 36(6): 603 - 607.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
A. Helander, M. Fors, and B. Zakrisson
STUDY OF AXIS-SHIELD NEW %CDT IMMUNOASSAY FOR QUANTIFICATION OF CARBOHYDRATE-DEFICIENT TRANSFERRIN (CDT) IN SERUM
Alcohol Alcohol., September 1, 2001; 36(5): 406 - 412.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Helander, G. Eriksson, H. Stibler, and J.-O. Jeppsson
Interference of Transferrin Isoform Types with Carbohydrate-deficient Transferrin Quantification in the Identification of Alcohol Abuse
Clin. Chem., July 1, 2001; 47(7): 1225 - 1233.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
M. Aalto, K. Seppa, P. Mattila, H. Mustonen, K. Ruuth, H. Hyvarinen, H. Pulkkinen, H. Alho, and P. Sillanaukee
Brief intervention for male heavy drinkers in routine general practice: a three-year randomized controlled study
Alcohol Alcohol., May 1, 2001; 36(3): 224 - 230.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
A. Berkowicz, S. Wallerstedt, K. Wall, and H. Denison
Carbohydrate-deficient transferrin in vitreous humour: a marker of possible withdrawal-related death in alcoholics
Alcohol Alcohol., May 1, 2001; 36(3): 231 - 234.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
N. Siegfried, C. D. H. Parry, N. K. Morojele, and D. Wason
Profile of drinking behaviour and comparison of self-report with the CAGE questionnaire and carbohydrate-deficient transferrin in a rural Lesotho community
Alcohol Alcohol., May 1, 2001; 36(3): 243 - 248.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
A. Gomez, A. Conde, J. A. Aguiar, J. M. Santana, A. Jorrin, and P. Betancor
Diagnostic usefulness of carbohydrate-deficient transferrin for detecting alcohol-related problems in hospitalized patients
Alcohol Alcohol., May 1, 2001; 36(3): 266 - 270.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Sillanaukee and U. Olsson
Improved Diagnostic Classification of Alcohol Abusers by Combining Carbohydrate-deficient Transferrin and {{gamma}}-Glutamyltransferase
Clin. Chem., April 1, 2001; 47(4): 681 - 685.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
B. Wuyts, J. R. Delanghe, I. Kasvosve, A. Wauters, H. Neels, and J. Janssens
Determination of Carbohydrate-deficient Transferrin Using Capillary Zone Electrophoresis
Clin. Chem., February 1, 2001; 47(2): 247 - 255.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
T. Arndt
Carbohydrate-deficient Transferrin as a Marker of Chronic Alcohol Abuse: A Critical Review of Preanalysis, Analysis, and Interpretation
Clin. Chem., January 1, 2001; 47(1): 13 - 27.
[Abstract] [Full Text] [PDF]


Home page
Am J EpidemiolHome page
P. Sillanaukee, N. Massot, P. Jousilahti, E. Vartiainen, J. Sundvall, U. Olsson, K. Poikolainen, M. Ponnio, J. P. Allen, and H. Alho
Dose Response of Laboratory Markers to Alcohol Consumption in a General Population
Am. J. Epidemiol., October 15, 2000; 152(8): 747 - 751.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
B. A. Johnson, J. D. Roache, M. A. Javors, C. C. DiClemente, C. R. Cloninger, T. J. Prihoda, P. S. Bordnick, N. Ait-Daoud, and J. Hensler
Ondansetron for Reduction of Drinking Among Biologically Predisposed Alcoholic Patients: A Randomized Controlled Trial
JAMA, August 23, 2000; 284(8): 963 - 971.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
L. Dibbelt
Does Trisialo-Transferrin Provide Valuable Information for the Laboratory Diagnosis of Chronically Increased Alcohol Consumption by Determination of Carbohydrate-deficient Transferrin?
Clin. Chem., August 1, 2000; 46(8): 1203 - 1205.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
R. Hackler, T. Arndt, A. Helwig-Rolig, J. Kropf, A. Steinmetz, and J. R. Schaefer
Investigation by Isoelectric Focusing of the Initial Carbohydrate-deficient Transferrin (CDT) and non-CDT Transferrin Isoform Fractionation Step Involved in Determination of CDT by the ChronAlcoI.D. Assay
Clin. Chem., April 1, 2000; 46(4): 483 - 492.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
B. Assmann, R. Hackler, V. Peters, J. R. Schaefer, and G. F. Hoffmann
Increased Carbohydrate-deficient Transferrin Concentration and Abnormal Protein Glycosylation of Unknown Etiology in a Patient with Achondroplasia
Clin. Chem., April 1, 2000; 46(4): 582 - 588.
[Full Text] [PDF]


Home page
J. Neurol. Neurosurg. PsychiatryHome page
G. Brathen, K. S Bjerve, E. Brodtkorb, and G. Bovim
Validity of carbohydrate deficient transferrin and other markers as diagnostic aids in the detection of alcohol related seizures
J. Neurol. Neurosurg. Psychiatry, March 1, 2000; 68(3): 342 - 348.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
H. Iturriaga, X. Lioi, and L. Valladares
SEX HORMONE-BINDING GLOBULIN IN NON-CIRRHOTIC ALCOHOLIC PATIENTS DURING EARLY WITHDRAWAL AND AFTER LONGER ABSTINENCE
Alcohol Alcohol., November 1, 1999; 34(6): 903 - 909.
[Abstract] [Full Text] [PDF]


Home page
Alcohol AlcoholHome page
J. Perdrix, P. Bovet, D. Larue, B. Yersin, B. Burnand, and F. Paccaud
PATTERNS OF ALCOHOL CONSUMPTION IN THE SEYCHELLES ISLANDS (INDIAN OCEAN)
Alcohol Alcohol., September 1, 1999; 34(5): 773 - 785.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
C. D. Spies and H. Rommelspacher
Alcohol Withdrawal in the Surgical Patient: Prevention and Treatment
Anesth. Analg., April 1, 1999; 88(4): 946 - 946.
[Full Text] [PDF]


Home page
Mol. Pharmacol.Home page
S. D. Lytton, A. Helander, Z.-Q. Zhang-Gouillon, K. Stokkeland, R. Bordone, S. Aricò, E. Albano, S. W. French, and M. Ingelman-Sundberg
Autoantibodies against Cytochromes P-4502E1 and P-4503A in Alcoholics
Mol. Pharmacol., February 1, 1999; 55(2): 223 - 233.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
A. Helander
Absolute or Relative Measurement of Carbohydrate-deficient Transferrin in Serum? Experiences with Three Immunological Assays
Clin. Chem., January 1, 1999; 45(1): 131 - 135.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
J. B. Whitfield, L. M. Fletcher, T. L. Murphy, L. W. Powell, J. Halliday, A. C. Heath, and N. G. Martin
Smoking, obesity, and hypertension alter the dose–response curve and test sensitivity of carbohydrate-deficient transferrin as a marker of alcohol intake
Clin. Chem., December 1, 1998; 44(12): 2480 - 2489.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. Helander, E. Vabo, K. Levin, and S. Borg
Intra- and interindividual variability of carbohydrate-deficient transferrin, {gamma}-glutamyltransferase, and mean corpuscular volume in teetotalers
Clin. Chem., October 1, 1998; 44(10): 2120 - 2125.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. van Pelt and H. Azimi
False-Positive CDTect Values in Patients with Low Ferritin Values
Clin. Chem., October 1, 1998; 44(10): 2219 - 2220.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
O. Martensson, E. Schink, and R. Brandt
Diurnal Variability and in Vitro Stability of Carbohydrate-deficient Transferrin
Clin. Chem., October 1, 1998; 44(10): 2226 - 2227.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
K. Viitala, K. Lahdesmaki, and O. Niemela
Comparison of the Axis %CDT TIA and the CDTect method as laboratory tests of alcohol abuse
Clin. Chem., June 1, 1998; 44(6): 1209 - 1215.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
F. W. C. Roelandse, N. van der Zwart, J. H. Didden, J. van Loon, and J. H. M. Souverijn
Detection of CSF Leakage by Isoelectric Focusing on Polyacrylamide Gel, Direct Immunofixation of Transferrins, and Silver Staining
Clin. Chem., February 1, 1998; 44(2): 351 - 353.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
T. Arndt, R. Hackler, T. O. Kleine, and A. M. Gressner
Validation by isoelectric focusing of the anion-exchange isotransferrin fractionation step involved in determination of carbohydrate-deficient transferrin by the CDTect assay
Clin. Chem., January 1, 1998; 44(1): 27 - 34.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. Laposata
Fatty acid ethyl esters: short-term and long-term serum markers of ethanol intake
Clin. Chem., August 1, 1997; 43(8): 1527 - 1534.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Bean, K. Liegmann, T. Lovli, C. Westby, and E. Sundrehagen
Semiautomated procedures for evaluation of carbohydrate-deficient transferrin in the diagnosis of alcohol abuse
Clin. Chem., June 1, 1997; 43(6): 983 - 989.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
F. Renner and R.-D. Kanitz
Quantification of carbohydrate-deficient transferrin by ion-exchange chromatography with an enzymatically prepared calibrator
Clin. Chem., March 1, 1997; 43(3): 485 - 490.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
T. Arndt, R. Hackler, T. Muller, T. O. Kleine, and A. M. Gressner
Increased serum concentration of carbohydrate-deficient transferrin in patients with combined pancreas and kidney transplantation
Clin. Chem., February 1, 1997; 43(2): 344 - 351.
[Abstract] [Full Text]