Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 37: 2053-2061, 1991;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bernert, J. T.
Right arrow Articles by Sampson, E. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bernert, J. T., Jr
Right arrow Articles by Sampson, E. J.

Clinical Chemistry, Vol 37, 2053-2061, Copyright © 1991 by American Association for Clinical Chemistry

Factors influencing the accuracy of the national reference system total cholesterol reference method

JT Bernert Jr, JR Akins, GR Cooper, AK Poulose, GL Myers and EJ Sampson
Division of Environmental Health Laboratory Sciences, Centers for Disease Control, U.S. Department of Health and Human Services, Atlanta, GA 30333.

Previous comparisons between the Reference and Definitive Methods for measuring serum cholesterol have demonstrated a small but persistent positive bias in the Reference Method, averaging about +1.6%. Here we describe the results of further investigations designed to better characterize the nature of this bias. Analysis of a well-characterized model serum sample (SRM 909) suggests that more than half of the difference in cholesterol values determined by the two methods is the result of small contributions from cholesterol precursor sterols and phytosterols, which are also measured for the Reference Method. An additional significant contribution may be from cholesterol oxidation products, particularly 7-hydroxycholesterol isomers, which are active in the Liebermann-Burchard reaction. The 7-hydroxycholesterol in SRM 909, most of which appeared to be already present in the serum rather than formed during saponification, may account for as much as 20% of the observed difference between the methods. Contributions from other possible sources, including impurities in the cholesterol standard and incomplete saponification of cholesteryl esters, are very small. Because the observed bias is both quite small and consistent among samples, the cholesterol Reference Method continues to meet all of the requirements generally expected for a dependable and effective Reference Method.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
G. L. Myers, M. M. Kimberly, P. P. Waymack, S. J. Smith, G. R. Cooper, and E. J. Sampson
A Reference Method Laboratory Network for Cholesterol: A Model for Standardization and Improvement of Clinical Laboratory Measurements
Clin. Chem., November 1, 2000; 46(11): 1762 - 1772.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. H. Eckfeldt and D. E. Bruns
Another Step Toward Standardization of Methods for Measuring Hemoglobin A1c
Clin. Chem., October 1, 1997; 43(10): 1811 - 1813.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Association for Clinical Chemistry.