Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 37: 210-215, 1991;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vaughan, M. A.
Right arrow Articles by Templeton, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vaughan, M. A.
Right arrow Articles by Templeton, D. M.

Clinical Chemistry, Vol 37, 210-215, Copyright © 1991 by American Association for Clinical Chemistry

Multielement analysis of biological samples by inductively coupled plasma-mass spectrometry. II. Rapid survey method for profiling trace elements in body fluids

MA Vaughan, AD Baines and DM Templeton
University of Toronto, Department of Clinical Biochemistry, Canada.

A rapid survey of the elements in biological materials, covering most of the elements in the periodic table, is possible by using available software for semi-quantitative analysis (SEMI-QUANT) by inductively coupled plasma-mass spectrometry. The procedure takes 5 min after sample preparation and gives results with a precision (CV) of approximately 20%. At a 10-fold dilution, 13 elements can be consistently and reliably detected in serum and 15 elements in whole- blood samples. At present the most important limitation of this method is mass overlap by polyatomic species for some elements of interest (e.g., Cr, Mn, and V). However, for the set of elements that can be reliably determined at endogenous concentrations, including Li, B, Mg, Fe, Cu, Zn, Rb, and Sr, the rapid scanning capability may be useful. Although matrix effects limit the direct interpretation of the semi- quantitative output, reasonable estimates of concentration are attainable by using matrix-matched standards or by adding a multielement standard to an aliquot from one sample in the set. We also present an example of determination of 25 elements in saliva from a patient with extensive dental work: Components of many of his dental alloys were readily identified. The method may also prove useful for screening multiple toxic exposures to heavier elements, such as Pb, Tl, Cd, and Hg.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Association for Clinical Chemistry.