Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 37: 273-276, 1991;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Banfi, G.
Right arrow Articles by Bonini, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Banfi, G.
Right arrow Articles by Bonini, P.

Clinical Chemistry, Vol 37, 273-276, Copyright © 1991 by American Association for Clinical Chemistry

Isotopic and nonisotopic assays for measuring somatotropin compared: re- evaluation of cutoff value in provocative tests

G Banfi, M Marinelli, E Casari, M Murone and P Bonini
Laboratorio Analisi, Istituto Scientifico H.S. Raffaele, Milano, Italy.

Measurement of human growth hormone (hGH; somatotropin) concentrations in serum after provocative tests is crucial for diagnosing deficiencies in production of this hormone. Serum hGH can be measured by various immunoassays, isotopic and nonisotopic, with monoclonal or polyclonal antibodies: a cutoff value of 10 micrograms/L after provocative testing is usually used to distinguish normal from hGH-deficient children. Previous studies demonstrated discrepancies in hGH measurement by different radioisotopic immunoassays. Here we evaluated the responses of six different commercial assays, radioisotopic and nonisotopic, with monoclonal or polyclonal antibodies in a series of 16 provocative tests (stimulation with clonidine) in short children. A wide range of discrepant values was obtained with the different kits. A cutoff of 10 micrograms/L produced discordance of diagnosis among assays for two children, whereas complete agreement was reached for a cutoff value of 7 micrograms/L. Parallelism tests performed with hGH international standard, pure recombinant hGH, and a serum with high hGH content suggest that heterogeneity of the antibodies used by the manufacturers, even among monoclonal antibodies, is the main source of discordant results. Cutoff values and reference values must be established separately for each method proposed for routine use.


The following articles in journals at HighWire Press have cited this article:


Home page
Eur J EndocrinolHome page
K. Pazaitou-Panayiotou, T. Kelesidis, I. Kelesidis, A. Kaprara, J. Blakeman, I. Vainas, A. Mpousoulegas, C. J Williams, and C. Mantzoros
Growth hormone-binding protein is directly and IGFBP-3 is inversely associated with risk of female breast cancer
Eur. J. Endocrinol., February 1, 2007; 156(2): 187 - 194.