Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 37: 723-728, 1991;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Neve, J.
Right arrow Articles by Leclercq, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Neve, J.
Right arrow Articles by Leclercq, N.

Clinical Chemistry, Vol 37, 723-728, Copyright © 1991 by American Association for Clinical Chemistry

Factors affecting determinations of manganese in serum by atomic absorption spectrometry

J Neve and N Leclercq
Department of Pharmaceutical Organic Chemistry, Free University of Brussels, Belgium.

A method was developed for the routine determination of manganese in serum from healthy human subjects by graphite furnace atomic absorption spectrometry. We controlled the experimental conditions rigorously, from sampling to analysis, to minimize contamination and to conserve diluted samples. We optimized the procedure with two serum Reference Materials, one of which had a manganese concentration very close to what is thought to be the physiological concentration in humans. The best analytical performance was obtained by directly injecting into the furnace serum diluted with an equal volume of a solution containing Triton X-100 and sodium EDTA and calibrating by the standard additions procedure or by a calibration graph constructed in a similar matrix. The Zeeman background correction produced better accuracy and precision than did the classical deuterium correction. Within-run CV for a manganese concentration of 12.7 nmol/L in serum was 7.9%, and between- run precision was 16.1%. The mean (SD) serum manganese concentration in 31 healthy adults was 10.8 (SD 3.0) nmol/L. Sex and age of subjects did not affect concentrations.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Association for Clinical Chemistry.