Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 37: 1338-1344, 1991;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bacon, B. L.
Right arrow Articles by Pardue, H. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bacon, B. L.
Right arrow Articles by Pardue, H. L.

Clinical Chemistry, Vol 37, 1338-1344, Copyright © 1991 by American Association for Clinical Chemistry

Predictive, error-compensating kinetic method for enzymatic quantification of creatinine in serum

BL Bacon and HL Pardue
Department of Chemistry, Purdue University, West Lafayette, IN 47907- 1393.

Here we describe an error-compensating kinetic-based method for the enzymatic quantification of creatinine in serum. The method, which has a large linear range and very low dependency on experimental variables that influence enzyme activity, is based on the use of creatinine amidohydrolase in a four-step coupled reaction sequence to generate a product that is monitored photometrically. We collected data for absorbance vs time during two to four half-lives of each reaction and fit a first-order model to the data to compute the total absorbance change that would be measured if the reaction were monitored to completion. Computed values of absorbance change agreed well with measured values and varied linearly with creatinine concentration in the sample throughout the range examined: 44 to 1326 mumol/L. A twofold change in enzyme activity in the final reaction mixture (3.3 to 6.6 kU/L) produced changes of only 12% and 4% for creatinine concentrations of 44 and 353 mumol/L, respectively. Results (y) for 39 serum samples that contained creatinine concentrations between 20 and 1800 mumol/L agreed well with liquid-chromatographic results (x), yielding linear least-squares statistics of y = (1.03 +/- 0.01) x + (5 +/- 5) mumol/L (r = 0.995, Sy.x = 37 mumol/L). We conclude that the predictive kinetic approach is a robust method for the quantification of creatinine in serum.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Association for Clinical Chemistry.