Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 37: 1345-1349, 1991;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Abe, A.
Right arrow Articles by Hamano, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Abe, A.
Right arrow Articles by Hamano, K.

Clinical Chemistry, Vol 37, 1345-1349, Copyright © 1991 by American Association for Clinical Chemistry

Automated measurement of amylase isoenzymes by a double kinetic assay with "blocked" beta-2-chloro-4-nitrophenyl maltopentaoside as substrate and with wheat germ inhibitor

A Abe, T Nishimura, A Noma and K Hamano
Department of Laboratory Medicine, Gifu University School of Medicine, Japan.

We evaluated the enzymic mechanism by which 3-keto butylidene-beta-2- chloro-4-nitrophenyl maltopentaoside (3KB-G5-CNP) serves as a substrate for serum pancreatic (p-) and salivary (s-) amylases. In aliquots of the reaction mixture, three kinds of beta-2-chloro-4-nitrophenyl oligosaccharides (glucose, maltoside, and maltotrioside) were separated from the substrate by high-performance liquid chromatography. Both isoenzymes behaved nearly identically and produced almost the same products. We automated a double kinetic procedure for determining total (t-) and p-amylase with use of a selective inhibitor from wheat germ in a single channel on the Hitachi 7050 analyzer. Within- and between-run CVs were, respectively, 0.5% and 1.7% for t-amylase (240 U/L), and 0.7% and 2.3% for p-amylase (230 U/L). The test results varied linearly with concentrations up to approximately 2000 U/L for t- and p-amylase activities. p/s ratios varied from 0.2 to 5.0. Results correlated well with those obtained by the monoclonal inhibition method (r = 0.992).





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Association for Clinical Chemistry.