Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 127-132, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lindqvist, U.
Right arrow Articles by Laurent, T. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lindqvist, U.
Right arrow Articles by Laurent, T. C.

Clinical Chemistry, Vol 38, 127-132, Copyright © 1992 by American Association for Clinical Chemistry

Seven different assays of hyaluronan compared for clinical utility

U Lindqvist, K Chichibu, B Delpech, RL Goldberg, W Knudson, AR Poole and TC Laurent
Department of Clinical Chemistry, University of Uppsala, Sweden.

To compare six assays of hyaluronan (hyaluronic acid; HYA) in serum, developed in different laboratories, we analyzed 10 samples from each of three groups: healthy persons, patients with primary biliary cirrhosis, and patients with rheumatoid arthritis. All the assays are based on the use of affinity proteins specific for HYA, prepared from cartilage or brain tissue, and are analogous to RIA or enzyme immunoassay techniques. The assay results were of the same magnitude. Although statistical analysis indicated that the methods in some cases deviated significantly from one another, this variation was less than the physiological variation in the healthy population. Therefore, the results of clinical investigations in which the various methods have been used are comparable. The analyses have high specificity and sensitivity for primary biliary cirrhosis but are somewhat less suitable for detecting rheumatoid arthritis. A seventh laboratory, which obtained antibodies to HYA, used these in an RIA to analyze a separate series of serum specimens. Results were in agreement with those obtained by one of the other assays.


The following articles in journals at HighWire Press have cited this article:


Home page
ThoraxHome page
M A Dentener, J H J Vernooy, S Hendriks, and E F M Wouters
Enhanced levels of hyaluronan in lungs of patients with COPD: relationship with lung function and local inflammation
Thorax, February 1, 2005; 60(2): 114 - 119.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.