Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 60-65, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Phillips, M.
Right arrow Articles by Greenberg, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Phillips, M.
Right arrow Articles by Greenberg, J.

Clinical Chemistry, Vol 38, 60-65, Copyright © 1992 by American Association for Clinical Chemistry

Ion-trap detection of volatile organic compounds in alveolar breath

M Phillips and J Greenberg
Department of Medicine, St. Vincent's Medical Center of Richmond, Staten Island, NY 10310.

We describe a method for the collection and microanalysis of the volatile organic compounds in human breath. A transportable apparatus supplies subjects with purified air and samples their alveolar breath; the volatile organic compounds are captured in an adsorptive trap containing activated carbon and molecular sieve. The sample is thermally desorbed from the trap in an automated microprocessor- controlled device, concentrated by two-stage cryofocusing, and assayed by gas chromatography with ion-trap detection. Compounds are identified by reference to a computer-based library of mass spectra with subtraction of the background components present in the inspired air. We used this device to study 10 normal subjects and determined the relative abundance of the volatile organic compounds in their alveolar breath. The breath-collecting apparatus was convenient to operate and was well tolerated by human volunteers.


The following articles in journals at HighWire Press have cited this article:


Home page
Indoor and Built EnvironmentHome page
A. Nilsson, A. R. Nosratabadi, V. Lagesson, N. Murgia, P. Leanderson, and C. Tagesson
Novel Technique for Measuring Low Molecular Weight Chemicals in Indoor Dust
Indoor and Built Environment, May 1, 2002; 11(3): 153 - 161.
[Abstract] [PDF]


Home page
J. Appl. Physiol.Home page
J. K. Schubert, K.-H. Spittler, G. Braun, K. Geiger, and J. Guttmann
CO2-controlled sampling of alveolar gas in mechanically ventilated patients
J Appl Physiol, February 1, 2001; 90(2): 486 - 492.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. Smith, P. Spanel, and S. Davies
Trace gases in breath of healthy volunteers when fasting and after a protein-calorie meal: a preliminary study
J Appl Physiol, November 1, 1999; 87(5): 1584 - 1588.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.