Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1968-1974, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jaouhari, J.
Right arrow Articles by Siest, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jaouhari, J.
Right arrow Articles by Siest, G.

Clinical Chemistry, Vol 38, 1968-1974, Copyright © 1992 by American Association for Clinical Chemistry

Avidin-biotin enzyme immunoassay of osteocalcin in serum or plasma

J Jaouhari, F Schiele, S Dragacci, P Tarallo, JP Siest, J Henny and G Siest
Laboratoire du Centre de Medecine Preventive, Vandoeuvre-les-Nancy, France.

We describe a competitive enzyme immunoassay, the ExtrAvidin-biotin system, for determining osteocalcin in human serum or plasma. Antibodies were raised against bovine osteocalcin. Binding of the antibodies to osteocalcin was calcium-dependent. Limit of detection is 0.07 nmol/L (0.4 microgram/L). The standard curve for method is linear between 0.3 and 17.6 nmol/L (1.9 and 100 micrograms/L). Interassay CV over the range 0.9 to 14.8 nmol/L (5.3 to 84 micrograms/L) is 7.5% to 11.7%. Analytical recovery is 105% +/- 5% (mean +/- SD). The measurement, which is adapted to microtiter plates, requires only 20 microL of serum and 5 h. The coefficient of correlation between the concentrations measured by this method and by a commercially available radioimmunoassay kit (CIS Biointernational) is 0.91. Osteocalcin can be measured in serum or heparinized plasma. Hemolysis (174 mumol/L hemoglobin) reduces osteocalcin concentration by 54%. High concentrations of triglycerides (7 mmol/L) give an overestimation of 63%. Serum concentrations of osteocalcin measured in 130 healthy subjects (ages 15-64 years) and 86 children (ages 4-14 years) were 1.4 +/- 0.8 and 4.0 +/- 1.5 nmol/L (8.1 +/- 4.6 and 22.5 +/- 8.6 micrograms/L), respectively (mean +/- SD).





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.