Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1995-2001, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ostapczuk, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ostapczuk, P.

Clinical Chemistry, Vol 38, 1995-2001, Copyright © 1992 by American Association for Clinical Chemistry

Direct determination of cadmium and lead in whole blood by potentiometric stripping analysis

P Ostapczuk
Institute of Applied Physical Chemistry, Research Center (KFA) Julich, FRG.

The commercially available equipment for potentiometric stripping analysis (PSA) was tested for routine lead and cadmium determination in whole-blood samples. In contrast to anodic stripping voltammetry, PSA is not subject to background interferences from organic electroactive constituents in the sample or to the presence of dissolved oxygen (i.e., oxygen removal is not necessary). To determine lead and cadmium by PSA, it is sufficient to dilute the blood sample with an appropriate supporting electrolyte (0.5 mol/L HCl). The detection limit changes with deposition time and volume of blood sample used. For 1 mL of blood and a 1-min deposition time, the detection limit is 1 microgram/L for both elements. If the deposition time increases to 10 min, cadmium can be determined at its normal concentration in blood (the detection limit is improved to < 0.1 microgram/L). Procedures for routine determination of lead and cadmium in whole blood are presented.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
E. Plotkin, J. F. McAleer, M. L. Cordeiro, M. R. Ackland, T. M. Sheehan, and R. A. Braithwaite
Convenient, Rapid Test for Lead in Blood with Use of Disposable Electrodes
Clin. Chem., November 1, 1997; 43(11): 2187 - 2189.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.