Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 2044-2054, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vessella, R. L.
Right arrow Articles by Lange, P. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vessella, R. L.
Right arrow Articles by Lange, P. H.

Clinical Chemistry, Vol 38, 2044-2054, Copyright © 1992 by American Association for Clinical Chemistry

Evaluation of the Abbott IMx automated immunoassay of prostate-specific antigen

RL Vessella, J Noteboom and PH Lange
Department of Urology, University of Washington Medical Center, Seattle 98195.

We detail the performance characteristics of the new IMx PSA immunoassay developed by Abbott Laboratories, addressing PSA recovery, assay reproducibility, standard curve storage, lower limit of detection, dilution linearity, and correlation with the Hybritech Tandem-R PSA immunoassay. We analyzed 686 sera for PSA retrospectively, testing 555 of these concurrently with the IMx and the Tandem-R immunoassays. The IMx PSA standard curve was linear from 0 to 100 micrograms/L, and curve storage was maintained for 4 weeks. The lower limit of detection of the IMx PSA assay was < or = 0.03 microgram/L; allowing for the assay precision yielded a biological detection limit of 0.06 microgram/L. We conservatively set the clinical threshold at 0.1 microgram/L. Regression analysis of dilution linearity involving 10 samples (0.44-200 micrograms/L) resulted in coefficients of correlation ranging from 0.9972 to 1.000. Reproducibility studies with 18 specimens within the range of 0.39-413.67 micrograms/L gave intra- and interassay CVs < 6.5%. The interassay 95% confidence interval for a specimen containing 0.06 microgram of PSA per liter was 0.03-0.09 microgram/L. Correlation between IMx and Tandem-R PSA assay results was excellent: r = 0.9909 and slope = 0.95. Overall, the IMx PSA immunoassay, with the conveniencies of automation, curve storage, and nonisotopic handling, provided an improved lower limit of PSA detection, which allows for earlier indication of residual or recurrent disease after radical prostatectomy.


The following articles in journals at HighWire Press have cited this article:


Home page
JCOHome page
P. Stattin, S. Rinaldi, C. Biessy, U.-H. Stenman, G. Hallmans, and R. Kaaks
High Levels of Circulating Insulin-Like Growth Factor-I Increase Prostate Cancer Risk: A Prospective Study in a Population-Based Nonscreened Cohort
J. Clin. Oncol., August 1, 2004; 22(15): 3104 - 3112.
[Abstract] [Full Text] [PDF]


Home page
JNCI J Natl Cancer InstHome page
P. Stattin, A. Bylund, S. Rinaldi, C. Biessy, H. Dechaud, U.-H. Stenman, L. Egevad, E. Riboli, G. Hallmans, and R. Kaaks
Plasma Insulin-Like Growth Factor-I, Insulin-Like Growth Factor-Binding Proteins, and Prostate Cancer Risk: a Prospective Study
J Natl Cancer Inst, December 6, 2000; 92(23): 1910 - 1917.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
H. Nagasaki, M. Watanabe, N. Komatsu, T. Kaneko, J. Y. Dube, T. Kajita, Y. Saitoh, and Y. Ohta
Epitope Analysis of a Prostate-specific Antigen (PSA) C-Terminal-specific Monoclonal Antibody and New Aspects for the Discrepancy between Equimolar and Skewed PSA Assays
Clin. Chem., April 1, 1999; 45(4): 486 - 496.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Magnusson, L. Larsson, G. Englund, B. Larsson, P. Strang, and L. Selin-Sjogren
Differences of bone alkaline phosphatase isoforms in metastatic bone disease and discrepant effects of clodronate on different skeletal sites indicated by the location of pain
Clin. Chem., August 1, 1998; 44(8): 1621 - 1628.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
S.-F. Chen, Y. Xu, and M. P.-C. Ip
Electrochemical Enzyme Immunoassay for Serum Prostate-Specific Antigen at Low Concentrations
Clin. Chem., August 1, 1997; 43(8): 1459 - 1461.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.