Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 2089-2092, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kessler, M. A.
Right arrow Articles by Wolfbeis, O. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kessler, M. A.
Right arrow Articles by Wolfbeis, O. S.

Clinical Chemistry, Vol 38, 2089-2092, Copyright © 1992 by American Association for Clinical Chemistry

Nonimmunological assay of urinary albumin based on laser-induced fluorescence

MA Kessler, MR Hubmann, BA Dremel and OS Wolfbeis
Analytical Division, Karl-Franzens University, Graz, Austria.

We describe the first nonimmunological assay of albumin in urine with a detection limit of 1 mg/L. The method is simple, rapid, and accurate. It is based on the probe Albumin Blue 670, which becomes highly fluorescent on binding to albumin. An inexpensive diode laser was used as the light source for measurement of laser-induced fluorescence. The assay was coupled to a flow-injection analysis system capable of running 20 samples per hour. The working range was 1-100 mg/L, which covered albumin concentrations found in nonpathological urine and in urine with slightly increased albumin. This range makes prediction of nephropathy possible at an early stage. Other serum proteins and hemoglobin do not interfere. The coefficients of variation were < 4% and < 7% within one day and from day to day, respectively. A correlation coefficient of 0.990 (n = 100) was obtained for comparison with the Behring nephelometric assay.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
S. Choi, E. Y. Choi, H. S. Kim, and S. W. Oh
On-Site Quantification of Human Urinary Albumin by a Fluorescence Immunoassay
Clin. Chem., June 1, 2004; 50(6): 1052 - 1055.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
M. A. Kessler, A. Meinitzer, W. Petek, and O. S. Wolfbeis
Microalbuminuria and borderline-increased albumin excretion determined with a centrifugal analyzer and the Albumin Blue 580 fluorescence assay
Clin. Chem., June 1, 1997; 43(6): 996 - 1002.
[Abstract] [Full Text] [PDF]