Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 2124-2129, 1992;
This Article
Right arrow Order Full text via Infotrieve
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ihara, H.
Right arrow Articles by Yoshida, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ihara, H.
Right arrow Articles by Yoshida, M.

Clinical Chemistry, Vol 38, 2124-2129, Copyright © 1992 by American Association for Clinical Chemistry

In vitro effects of light on serum bilirubin subfractions measured by high-performance liquid chromatography: comparison with four routine methods

H Ihara, H Nakamura, Y Aoki, T Aoki and M Yoshida
Department of Laboratory Medicine, Toho University, Tokyo, Japan.

The effects of light on serum bilirubin subfractions in vitro were investigated by HPLC and four routine methods for bilirubin analysis. By HPLC, the rate of photodegradation of unconjugated bilirubin (Bu) was nearly twice that of monoconjugated bilirubin (mBc) and threefold that of diconjugated bilirubin (dBc); delta bilirubin (Bd) was most stable against photoirradiation. In the diazo method, the rate of photodegradation of direct bilirubin was almost the same as that of the sum of mBc, dBc, and Bd determined by the HPLC method. However, the rate of photodegradation of indirect bilirubin was significantly lower (P < 0.001) than that obtained by HPLC, because approximately 30% of the bilirubin photoproducts reacted with the diazo reagent as indirect bilirubin. The rate of photodegradation of total bilirubin determined by the direct spectrometric method was lower than that determined by the diazo method, but equal to that of the total peak areas of HPLC. In the Ektachem method, bilirubin photoproducts affected total bilirubin negligibly, and Bc and Bu positively, so that the value of Bd decreased. In the bilirubin oxidase method, bilirubin photoproducts were oxidized enzymatically by both the total and direct bilirubin reagents. We re-emphasize the importance of shielding serum from light to avoid generating bilirubin photoproducts that interfere with the accurate determination of serum bilirubin subfractions. We also recommend HPLC analysis as a standard method for bilirubin measurement.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.