|
|
||||||||
Clinical Chemistry, Vol 38, 2414-2418, Copyright © 1992 by American Association for Clinical Chemistry
GS Bodor, RR Little, N Garrett, W Brown, DE Goldstein and MH Nahm
Washington University School of Medicine, Department of Pathology, St. Louis, MO 63110.
Measurement of glycohemoglobin has been recommended for the long-term assessment of glycemic control in diabetic patients. Because different analytical methods measure different glycohemoglobin species, it has been difficult to compare results between laboratories. Here we report 3 years of experience with calibration of an affinity chromatography method for measuring total glycohemoglobin (GHb). Calibration was achieved by including in each assay three hemolysate calibrators for which values for HbA1c and GHb had been determined by repeated analyses by high-performance liquid chromatography (HPLC) and affinity chromatography, respectively. Calibration improved interassay precision (CV = 3.20-7.90% and < 5.0% before and after the introduction of calibration, respectively) and eliminated lot-to-lot variability. In 91 samples, HbA1c was estimated by the calibrated affinity chromatography assay and measured by an ion-exchange HPLC method. Estimated and HPLC- measured HbA1c showed no clinically significant differences during 36 months. The high degree of long-term precision, the disappearance of lot-to-lot variability, and the excellent comparability between analytical methods measuring different species of glycated hemoglobins demonstrate the advantages of calibration.
The following articles in journals at HighWire Press have cited this article:
![]() |
D. E. Goldstein, R. R. Little, R. A. Lorenz, J. I. Malone, D. Nathan, C. M. Peterson, and D. B. Sacks Tests of Glycemia in Diabetes Diabetes Care, July 1, 2004; 27(7): 1761 - 1773. [Full Text] [PDF] |
||||
![]() |
A. Kirk, N. Mutrie, P. MacIntyre, and M. Fisher Increasing Physical Activity in People With Type 2 Diabetes Diabetes Care, April 1, 2003; 26(4): 1186 - 1192. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. B. Sacks, D. E. Bruns, D. E. Goldstein, N. K. Maclaren, J. M. McDonald, and M. Parrott Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus Clin. Chem., March 1, 2002; 48(3): 436 - 472. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Chen, D. L. Crimmins, F. F. Hsu, F. P. Lindberg, and M. G. Scott Hemoglobin Raleigh as the cause of a falsely increased hemoglobin A1C in an automated ion-exchange HPLC method Clin. Chem., June 1, 1998; 44(6): 1296 - 1301. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Gerlo and F. Gorus Calibration of ion-exchange HPLC measurements of glycohemoglobin: effect on interassay precision Clin. Chem., December 1, 1997; 43(12): 2353 - 2357. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Halwachs-Baumann, S. Katzensteiner, W. Schnedl, P. Purstner, T. Pieber, and M. Wilders-Truschnig Comparative evaluation of three assay systems for automated determination of hemoglobin A1c Clin. Chem., March 1, 1997; 43(3): 511 - 517. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. L. Arfken, A. E. Salicrup, S. M. Meuer, L. V. D. Priore, R. Klein, J. B. McGill, C. S. Rucker, N. H. White, and J. V. Santiago Retinopathy in African Americans and Whites With Insulin-Dependent Diabetes Mellitus Arch Intern Med, November 28, 1994; 154(22): 2597 - 2602. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |