Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 2414-2418, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bodor, G. S.
Right arrow Articles by Nahm, M. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bodor, G. S.
Right arrow Articles by Nahm, M. H.

Clinical Chemistry, Vol 38, 2414-2418, Copyright © 1992 by American Association for Clinical Chemistry

Standardization of glycohemoglobin determinations in the clinical laboratory: three years of experience

GS Bodor, RR Little, N Garrett, W Brown, DE Goldstein and MH Nahm
Washington University School of Medicine, Department of Pathology, St. Louis, MO 63110.

Measurement of glycohemoglobin has been recommended for the long-term assessment of glycemic control in diabetic patients. Because different analytical methods measure different glycohemoglobin species, it has been difficult to compare results between laboratories. Here we report 3 years of experience with calibration of an affinity chromatography method for measuring total glycohemoglobin (GHb). Calibration was achieved by including in each assay three hemolysate calibrators for which values for HbA1c and GHb had been determined by repeated analyses by high-performance liquid chromatography (HPLC) and affinity chromatography, respectively. Calibration improved interassay precision (CV = 3.20-7.90% and < 5.0% before and after the introduction of calibration, respectively) and eliminated lot-to-lot variability. In 91 samples, HbA1c was estimated by the calibrated affinity chromatography assay and measured by an ion-exchange HPLC method. Estimated and HPLC- measured HbA1c showed no clinically significant differences during 36 months. The high degree of long-term precision, the disappearance of lot-to-lot variability, and the excellent comparability between analytical methods measuring different species of glycated hemoglobins demonstrate the advantages of calibration.


The following articles in journals at HighWire Press have cited this article:


Home page
Diabetes CareHome page
D. E. Goldstein, R. R. Little, R. A. Lorenz, J. I. Malone, D. Nathan, C. M. Peterson, and D. B. Sacks
Tests of Glycemia in Diabetes
Diabetes Care, July 1, 2004; 27(7): 1761 - 1773.
[Full Text] [PDF]


Home page
Diabetes CareHome page
A. Kirk, N. Mutrie, P. MacIntyre, and M. Fisher
Increasing Physical Activity in People With Type 2 Diabetes
Diabetes Care, April 1, 2003; 26(4): 1186 - 1192.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. B. Sacks, D. E. Bruns, D. E. Goldstein, N. K. Maclaren, J. M. McDonald, and M. Parrott
Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus
Clin. Chem., March 1, 2002; 48(3): 436 - 472.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. Chen, D. L. Crimmins, F. F. Hsu, F. P. Lindberg, and M. G. Scott
Hemoglobin Raleigh as the cause of a falsely increased hemoglobin A1C in an automated ion-exchange HPLC method
Clin. Chem., June 1, 1998; 44(6): 1296 - 1301.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
E. Gerlo and F. Gorus
Calibration of ion-exchange HPLC measurements of glycohemoglobin: effect on interassay precision
Clin. Chem., December 1, 1997; 43(12): 2353 - 2357.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
G. Halwachs-Baumann, S. Katzensteiner, W. Schnedl, P. Purstner, T. Pieber, and M. Wilders-Truschnig
Comparative evaluation of three assay systems for automated determination of hemoglobin A1c
Clin. Chem., March 1, 1997; 43(3): 511 - 517.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.