Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 580-584, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Urdal, P.
Right arrow Articles by Hjortdahl, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Urdal, P.
Right arrow Articles by Hjortdahl, P.

Clinical Chemistry, Vol 38, 580-584, Copyright © 1992 by American Association for Clinical Chemistry

Rapid immunometric measurement of C-reactive protein in whole blood

P Urdal, SM Borch, S Landaas, MB Krutnes, GO Gogstad and P Hjortdahl
Department of Clinical Chemistry, Ulleval Hospital, Oslo, Norway.

We examined an instrument-free test for C-reactive protein (CRP) in whole blood. The NycoCard CRP Whole Blood test uses a cell-solubilizing dilution liquid, a membrane-bound antibody that binds CRP, and a gold- conjugated antibody for making visible the bound CRP. We obtained essentially identical dose-response curves in citrate-, heparin-, and EDTA-treated blood. CVs were 6.7-12.5% within series and 10.1-14.7% between series. The detection limit was 12 mg/L. Intralipid added to blood increased measured CRP by 10-20%, whereas no change was seen with added bilirubin, added serum amyloid P component, or the presence of rheumatoid factor. In 234 patients' blood samples the results of the NycoCard Whole Blood test correlated well (r = 0.96) with those of a turbidimetric serum method. The test allows reliable measurement of CRP from a small volume of whole blood (25 microL) without using expensive equipment; it should be useful for decentralized testing in hospital departments, emergency units, and primary health care centers.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
P. Tarkkinen, T. Palenius, and T. Lovgren
Ultrarapid, Ultrasensitive One-Step Kinetic Immunoassay for C-Reactive Protein (CRP) in Whole Blood Samples: Measurement of the Entire CRP Concentration Range with a Single Sample Dilution
Clin. Chem., February 1, 2002; 48(2): 269 - 277.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J.-F. Benoist, D. Orbach, and D. Biou
False increase in C-reactive protein attributable to heterophilic antibodies in two renal transplant patients treated with rabbit antilymphocyte globulin
Clin. Chem., September 1, 1998; 44(9): 1980 - 1985.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
B. S. Dahler-Eriksen, J. F. Lassen, P. H. Petersen, E. D. Lund, T. Lauritzen, and I. Brandslund
Evaluation of a near-patient test for C-reactive protein used in daily routine in primary healthcare by use of difference plots
Clin. Chem., November 1, 1997; 43(11): 2064 - 2075.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.