Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 619-623, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Orsonneau, J. L.
Right arrow Articles by Lustenberger, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Orsonneau, J. L.
Right arrow Articles by Lustenberger, P.

Clinical Chemistry, Vol 38, 619-623, Copyright © 1992 by American Association for Clinical Chemistry

Simple and sensitive determination of urea in serum and urine

JL Orsonneau, C Massoubre, M Cabanes and P Lustenberger
Laboratoire de Chimie A, C.H.R. Hotel-Dieu, Nantes, France.

In this method for serum and urinary urea determination, the same reagent is used without predilution of urine samples. The method is based on the pH increase resulting from the ammonia released by urease hydrolysis of urea. o-Cresolphthalein complexone is used to monitor the pH change colorimetrically. Urea concentration and absorbance at 570 nm are linearly related for concentrations as great as 600 mmol/L for urine samples and 100 mmol/L for serum. There are no clinically significant interferences from physiological substances or drugs, and precision and accuracy are excellent (CV approximately 2%, except at very low concentrations in serum; analytical recovery was 99% in urine, 100% in serum). Results by this method (y) and by the Astra method (x) for urine correlated well (y = 0.991x - 2.87, Sy/x = 9.21, r = 0.994), as did the results by this method and by the total enzymatic method (x') for serum (y = 1.002x' + 0.192, Sy/x' = 0.598, r = 0.997). This method is applicable to automated as well as manual instruments, and one-reagent or two-reagent formats can be used.


The following articles in journals at HighWire Press have cited this article:


Home page
Am. J. Clin. Nutr.Home page
N. D Luscombe-Marsh, M. Noakes, G. A Wittert, J. B Keogh, P. Foster, and P. M Clifton
Carbohydrate-restricted diets high in either monounsaturated fat or protein are equally effective at promoting fat loss and improving blood lipids
Am. J. Clinical Nutrition, April 1, 2005; 81(4): 762 - 772.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
E. Farnsworth, N. D Luscombe, M. Noakes, G. Wittert, E. Argyiou, and P. M Clifton
Effect of a high-protein, energy-restricted diet on body composition, glycemic control, and lipid concentrations in overweight and obese hyperinsulinemic men and women
Am. J. Clinical Nutrition, July 1, 2003; 78(1): 31 - 39.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.