Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1210-1217, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rej, R.
Right arrow Articles by Jenny, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rej, R.
Right arrow Articles by Jenny, R. W.

Clinical Chemistry, Vol 38, 1210-1217, Copyright © 1992 by American Association for Clinical Chemistry

How good are clinical laboratories? An assessment of current performance [published erratum appears in Clin Chem 1993 Mar;39(3):558]

R Rej and RW Jenny
Wadsworth Center for Laboratories and Research, New York State Department of Health, Albany.

The Clinical Laboratory Improvement Act of 1967 and Amendments of 1988 (CLIA '67 and CLIA '88) were enacted to ensure that clinical laboratories within the U.S. provide a quality of service that meets clinical needs for good patient care. Approved proficiency-testing programs are to judge the quality of laboratory testing by promulgated performance criteria. We examine the quality of analytical results reported in 1991 to the New York State Department of Health Proficiency Testing program in light of these criteria and analytical goals, based on medical usefulness. Analytical performance is examined for cholesterol, potassium, sodium, calcium, glucose, aspartate aminotransferase, digoxin, and theophylline. In general, proposed CLIA '88 performance standards are compatible with the current state of practice for the population of laboratories examined. Exceptions appear to be digoxin and sodium (failure rate exceeding average) and most therapeutic substances (low failure rate). Sources of analytical bias relative to an accuracy-based target value must be characterized as method-, laboratory-, or matrix-dependent if regulatory programs are to achieve the objective of improving analytical accuracy across all testing sites.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.