Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1307-1310, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Murthy, J. N.
Right arrow Articles by Soldin, S. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Murthy, J. N.
Right arrow Articles by Soldin, S. J.

Clinical Chemistry, Vol 38, 1307-1310, Copyright © 1992 by American Association for Clinical Chemistry

Radioreceptor assay for quantifying FK-506 immunosuppressant in whole blood

JN Murthy, Y Chen, VS Warty, R Venkataramanan, JG Donnelly, A Zeevi and SJ Soldin
Department of Laboratory Medicine, Children's National Medical Center, Washington, DC 20010.

We describe a quantitative radioreceptor assay (RRA) for quantifying FK- 506 in whole blood. FK-506 extracted from whole blood with a cyclohexyl- sorbent column competes with [3H]dihydro-FK-506 for binding to a partially purified preparation of FK-506 binding protein (FK-BP). Free and protein-bound FK-506 are separated on LH 20 Sephadex chromatographic columns. We compared the results of this method with those of an enzyme immunoassay that uses a monoclonal antibody: r = 0.97, Sy/x = 0.039. Between-day precisions (CV) at FK-506 concentrations of 8 and 17 micrograms/L were 9.2% and 8.2%, respectively. Within-run precisions were 5.9%, 8.1%, and 9.4%, respectively, at 4, 8, and 15 micrograms/L. Analytical recovery, evaluated at 5, 10, 15, 20, and 25 micrograms/L for FK-506 added to whole blood, ranged from 98% to 103%. The assay can reliably quantify FK-506 blood concentrations between 1.0 and 25 micrograms/L.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
G. D. MacFarlane, D. G. Scheller, D. L. Ersfeld, L. M. Shaw, R. Venkatarmanan, L. Sarkozi, R. Mullins, and B. R. Fox
Analytical Validation of the PRO-Trac II ELISA for the Determination of Tacrolimus (FK506) in Whole Blood
Clin. Chem., September 1, 1999; 45(9): 1449 - 1458.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
J. F. GUMMERT, T. IKONEN, and R. E. MORRIS
Newer Immunosuppressive Drugs: A Review
J. Am. Soc. Nephrol., June 1, 1999; 10(6): 1366 - 1380.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.