Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1350-1352, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Aoki, Y.
Right arrow Articles by Yoshida, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aoki, Y.
Right arrow Articles by Yoshida, M.

Clinical Chemistry, Vol 38, 1350-1352, Copyright © 1992 by American Association for Clinical Chemistry

Effects of serum bilirubin on determination of uric acid by the uricase- peroxidase coupled reaction

Y Aoki, H Ihara, H Nakamura, T Aoki and M Yoshida
Department of Laboratory Medicine, Toho University, Ohashi Hospital, Tokyo, Japan.

We examined the possible effect of different bilirubin species, including unconjugated (Bu), sugar-conjugated (Bc), and authentic delta bilirubin (Bd) isolated from serum, on the direct enzymatic measurement of uric acid by using the uricase (EC 1.7.3.3) and peroxidase (EC 1.11.1.7) coupled reaction. Bc, isolated from human bile, produced the most interference with uric acid determination. Although the presence of human serum albumin reduced interference by Bu and Bc, albumin-bound Bc complex still produced greater interference than Bu. Interference with the peroxidase reaction by Bc covalently bound to serum albumin (Bd) was less than that by Bu. We examined this phenomenon by using serum-isolated Bd obtained by ammonium sulfate precipitation and ultrafiltration and by using commercially available ditaurobilirubin (DTB) and chemically synthesized Bd (via Woodward's reagent, WBd) as surrogates for bile-isolated Bc and natural Bd, respectively. DTB produced the same amount of interference as natural Bc, but the interference produced by DTB in the presence of serum albumin was not the same as that produced by natural Bc with albumin. Our synthetic Bd appears to be a reliable surrogate for natural Bd in testing for bilirubin interference.