Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1360-1364, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Steinke, J. M.
Right arrow Articles by Shepherd, A. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Steinke, J. M.
Right arrow Articles by Shepherd, A. P.

Clinical Chemistry, Vol 38, 1360-1364, Copyright © 1992 by American Association for Clinical Chemistry

Effects of temperature on optical absorbance spectra of oxy-, carboxy-, and deoxyhemoglobin

JM Steinke and AP Shepherd
Department of Physiology, University of Texas Health Science Center, San Antonio 78284-7756.

The optical absorbance spectra of oxy-, carboxy-, and deoxyhemoglobin were recorded at wavelengths from 479 to 651 nm and at temperatures of 20, 30, and 40 degrees C. As noted in earlier reports, a major effect of lowering the temperature was an increase in the absorptivities at or near the absorbance maxima. However, at other wavelengths, reducing the temperature increased, decreased, or caused no change in absorbance. At wavelengths where temperature-induced shifts did occur, the absorbance change appeared to be a linear function of temperature. Unlike previous reports, the data presented here are quantitative and thus can be used to predict temperature-induced errors in spectrophotometric measurements of the relative concentrations of these hemoglobin species. Examples are given of the error that would occur in a widely used CO-Oximeter, the IL482, if it were not temperature controlled. Thus, the data presented here should be particularly useful to the operators and designers of spectrophotometric instruments such as oximeters, CO-Oximeters, and hemoglobinometers.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
B. H. A. Maas, A. Buursma, R. A. J. Ernst, A. H. J. Maas, and W. G. Zijlstra
Lyophilized bovine hemoglobin as a possible reference material for the determination of hemoglobin derivatives in human blood
Clin. Chem., November 1, 1998; 44(11): 2331 - 2339.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
N. Yukawa, T. Suzuoka, T. Saito, A. R. W. Forrest, M. Osawa, S. Takeichi, J. A. Brunelle, and R. F. Moran
Data Processing in CO-Oximeters That Use Overdetermined Systems • A manufacturer replies:
Clin. Chem., January 1, 1997; 43(1): 189 - 191.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.