Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1474-1478, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hill, B. M.
Right arrow Articles by Hassemer, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hill, B. M.
Right arrow Articles by Hassemer, D. J.

Clinical Chemistry, Vol 38, 1474-1478, Copyright © 1992 by American Association for Clinical Chemistry

Comparison of plastic vs. glass evacuated serum-separator (SST) blood- drawing tubes for common clinical chemistry determinations

BM Hill, RH Laessig, DD Koch and DJ Hassemer
Wisconsin State Laboratory of Hygiene, University of Wisconsin, Madison.

We evaluated a plastic evacuated blood-drawing tube containing an integral serum-separating barrier gel, by direct comparison with a glass counterpart. The plastic tube demonstrated no differences when compared for common clinical chemistry analytes with multiple types of instruments and systems. A total of 260 such different combinations were studied with emphasis on tests sensitive to drawing and handling indexes such as lactate dehydrogenase and potassium. A total of six separate blood drawings were tested with no significant differences noted in these tests. The total study included subjective evaluations of the plastic tube's use as a blood-drawing device and objective studies based on quantitative test results from normal and hospitalized patients and use of the primary sampling tubes (both plastic and glass) for 48-h storage.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
M. Rynning, T. Wentzel-Larsen, and B. J. Bolann
A Model for an Uncertainty Budget for Preanalytical Variables in Clinical Chemistry Analyses
Clin. Chem., July 1, 2007; 53(7): 1343 - 1348.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. K. Stankovic and G. Parmar
Assay interferences from blood collection tubes: a cautionary note.
Clin. Chem., August 1, 2006; 52(8): 1627 - 1628.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
R. A.R. Bowen, Y. Chan, J. Cohen, N. N. Rehak, G. L. Hortin, G. Csako, and A. T. Remaley
Effect of Blood Collection Tubes on Total Triiodothyronine and Other Laboratory Assays
Clin. Chem., February 1, 2005; 51(2): 424 - 433.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
S. K. Drake, R. A.R. Bowen, A. T. Remaley, and G. L. Hortin
Potential Interferences from Blood Collection Tubes in Mass Spectrometric Analyses of Serum Polypeptides
Clin. Chem., December 1, 2004; 50(12): 2398 - 2401.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.