Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1479-1482, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ashworth, L.
Right arrow Articles by Alberti, K. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ashworth, L.
Right arrow Articles by Alberti, K. G.

Clinical Chemistry, Vol 38, 1479-1482, Copyright © 1992 by American Association for Clinical Chemistry

HemoCue: evaluation of a portable photometric system for determining glucose in whole blood

L Ashworth, I Gibb and KG Alberti
Department of Medicine, Medical School, University of Newcastle upon Tyne, UK.

We assessed the HemoCue system for measuring glucose in 5 microL of whole blood. A glucose dehydrogenase-based reaction is used with dried reagents contained in disposable microcuvettes, which are filled with blood by capillary action. Automated hexokinase and YSI 23AM glucose analyzer methods were used for comparison. Overall imprecision (CV) was better than 4.5%, with no significant differences in results between three different HemoCue photometers and four batches of microcuvettes. Regression slopes (+/- SE) were 0.947 (0.011) with the YSI and 0.966 (0.015) with the hexokinase method. Analytical recovery of added glucose was 101-106%, and the system functioned with hematocrits up to 0.65. Bilirubin up to 453 mumol/L did not interfere, but high concentrations of endogenous (greater than 3 mmol/L) and exogenous triglycerides gave positive interference. The system proved stable and robust under a wide range of storage and handling conditions; performance was impaired only at high ambient temperature (37 degrees C). We conclude that the HemoCue system should prove useful for glucose measurement; further testing outside the laboratory is warranted.


The following articles in journals at HighWire Press have cited this article:


Home page
Diabetes CareHome page
K. Dungan, J. Chapman, S. S. Braithwaite, and J. Buse
Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management
Diabetes Care, February 1, 2007; 30(2): 403 - 409.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
M. J. Pugia, G. Blankenstein, R.-P. Peters, J. A. Profitt, K. Kadel, T. Willms, R. Sommer, H. H. Kuo, and L. S. Schulman
Microfluidic Tool Box as Technology Platform for Hand-Held Diagnostics
Clin. Chem., October 1, 2005; 51(10): 1923 - 1932.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
G. B.B. Kristensen, N. G. Christensen, G. Thue, and S. Sandberg
Between-Lot Variation in External Quality Assessment of Glucose: Clinical Importance and Effect on Participant Performance Evaluation
Clin. Chem., September 1, 2005; 51(9): 1632 - 1636.
[Abstract] [Full Text] [PDF]


Home page
Eur J EndocrinolHome page
A. D M Stork, H. Kemperman, D W. Erkelens, and T. F Veneman
Comparison of the accuracy of the hemocue glucose analyzer with the Yellow Springs Instrument glucose oxidase analyzer, particularly in hypoglycemia
Eur. J. Endocrinol., August 1, 2005; 153(2): 275 - 281.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
A. M.W. Spijkerman, M. C. Adriaanse, J. M. Dekker, G. Nijpels, C. D.A. Stehouwer, L. M. Bouter, and R. J. Heine
Diabetic Patients Detected by Population-Based Stepwise Screening Already Have a Diabetic Cardiovascular Risk Profile
Diabetes Care, October 1, 2002; 25(10): 1784 - 1789.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. L. M. Lynch and M. J. O'Kane
Methemoglobin Interferes with the HemoCue B-Glucose Analyzer
Clin. Chem., March 1, 2002; 48(3): 581 - 583.
[Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
B. Bülow, L. Hagmar, J. Eskilsson, and E. M. Erfurth
Hypopituitary Females Have a High Incidence of Cardiovascular Morbidity and an Increased Prevalence of Cardiovascular Risk Factors
J. Clin. Endocrinol. Metab., February 1, 2000; 85(2): 574 - 584.
[Abstract] [Full Text]


Home page
Reproductive SciencesHome page
F. Y. Teng, O. Punla, and B. J. Koos
Predictive Value of HemoCue Capillary Whole Blood Glucose Measurements in Pregnancy
Reproductive Sciences, July 1, 1995; 2(4): 618 - 622.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.