Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1488-1490, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Philcox, J. C.
Right arrow Articles by Rofe, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Philcox, J. C.
Right arrow Articles by Rofe, A. M.

Clinical Chemistry, Vol 38, 1488-1490, Copyright © 1992 by American Association for Clinical Chemistry

Hemoglobin A1c by HPLC with the Pharmacia Mono S HR 5/N cation-exchange column: influence of sample protein load on optimal chromatographic conditions

JC Philcox, MR Haywood and AM Rofe
Division of Clinical Chemistry, Institute of Medical and Veterinary Science, Adelaide, South Australia.

The Pharmacia Mono S HR 5/5 column has been optimized for hemoglobin A1c analysis by HPLC by using a much smaller column load, decreased buffer flow rate, and a steeper gradient than was used in previously described methods. Superior chromatographic separation, shorter analysis time, and a greatly extended column life have resulted.


The following articles in journals at HighWire Press have cited this article:


Home page
Postgrad. Med. J.Home page
Low HbA1c levels in a poorly controlled diabetic
Postgrad. Med. J., July 1, 2003; 79(933): 421 - 421.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
G. Phillipov and P. J. Phillips
Components of Total Measurement Error for Hemoglobin A1c Determination
Clin. Chem., October 1, 2001; 47(10): 1851 - 1853.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
E. Gerlo and F. Gorus
Calibration of ion-exchange HPLC measurements of glycohemoglobin: effect on interassay precision
Clin. Chem., December 1, 1997; 43(12): 2353 - 2357.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.