Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1596-1600, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ginsberg, B. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ginsberg, B. H.

Clinical Chemistry, Vol 38, 1596-1600, Copyright © 1992 by American Association for Clinical Chemistry

An overview of minimally invasive technologies [published erratum appears in Clin Chem 1992 Nov;38(11):2360]

BH Ginsberg
Becton Dickinson and Company, Franklin Lakes, NJ 07417.

Self-measurement of blood glucose is an integral part of diabetes mellitus therapy. As many as 65% of diabetic people (4-5 million people) perform some degree of self-monitoring and approximately 20-30% do so frequently. Most patients consider this the most onerous part of their diabetes therapy. It requires obtaining blood, frequently in public, and is usually the most painful part of therapy, being significantly more painful than insulin self-administration. Patients therefore are anxious for a less-invasive method for glucose measurement. Methods exist or are being developed for minimally invasive glucose monitoring, which use body fluids other than blood (e.g., sweat and saliva), subcutaneous tissue, or blood measured less invasively. Sweat and saliva are relatively easily obtained but their glucose concentration lags significantly behind blood glucose. Methods to increase sweating have been developed and seem to increase the timeliness of the sweat glucose measurement. Subcutaneous glucose measurement seems to lag only a few minutes behind blood glucose and may actually be a better measurement of the critical values of glucose concentrations in brain, muscle, and other tissue. Glucose can be measured by noninvasive or minimally invasive methods, such as those making skin or mucous membranes permeable to glucose or those placing a reporter molecule in the subcutaneous tissue. Needle-type sensors have been improved in accuracy, size, and stability and can be placed into the subcutaneous tissue or peripheral veins to monitor blood glucose with miniature instruments.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
W. E. Winter
A Rosetta Stone for Insulin Treatment: Self-Monitoring of Blood Glucose
Clin. Chem., June 1, 2004; 50(6): 985 - 987.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
M. E. Collison, P. J. Stout, T. S. Glushko, K. N. Pokela, D. J. Mullins-Hirte, J. R. Racchini, M. A. Walter, S. P. Mecca, J. Rundquist, J. J. Allen, et al.
Analytical Characterization of Electrochemical Biosensor Test Strips for Measurement of Glucose in Low-Volume Interstitial Fluid Samples
Clin. Chem., September 1, 1999; 45(9): 1665 - 1673.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
O. S. Khalil
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Clin. Chem., February 1, 1999; 45(2): 165 - 177.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association for Clinical Chemistry.