Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1665-1670, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schembri, C. T.
Right arrow Articles by Buhl, S. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schembri, C. T.
Right arrow Articles by Buhl, S. N.

Clinical Chemistry, Vol 38, 1665-1670, Copyright © 1992 by American Association for Clinical Chemistry

Portable simultaneous multiple analyte whole-blood analyzer for point- of-care testing

CT Schembri, V Ostoich, PJ Lingane, TL Burd and SN Buhl
Abaxis, Sunnyvale, CA 94089.

We describe a portable clinical chemistry analyzer for point-of-care measurements of multiple analytes in less than 10 min from approximately 40 microL of whole blood (fingerstick or venous). Whole blood is applied directly to a 7.9-cm-diameter, single-use plastic rotor containing liquid diluent and greater than or equal to 4-12 tests in the form of 1- to 2-mm-diameter dry reagent beads. The reagent/rotor is immediately placed in a portable instrument along with a ticket/label results card. As the instrument spins the rotor, capillary and rotational forces process the blood into diluted plasma, distribute the patient's diluted sample to cuvettes containing the reagent beads, and mix the diluted sample with the reagents. The instrument monitors the chemical reactions optically at nine wavelengths; sample volume and temperature are also measured optically. The calibration data for each reagent are read from a bar code on the periphery of each rotor. The instrument processes all the measurements to calculate, store, print, and communicate the results. Each reagent/rotor contains an enzymatic control that must be within a defined range before the results from that analysis are reported.