Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1678-1684, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Buechler, K. F.
Right arrow Articles by Lee, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Buechler, K. F.
Right arrow Articles by Lee, T.

Clinical Chemistry, Vol 38, 1678-1684, Copyright © 1992 by American Association for Clinical Chemistry

Simultaneous detection of seven drugs of abuse by the Triage panel for drugs of abuse

KF Buechler, S Moi, B Noar, D McGrath, J Villela, M Clancy, A Shenhav, A Colleymore, G Valkirs and T Lee
Biosite Diagnostics, Inc., San Diego, CA 92121.

This novel, competitive immunoassay simultaneously detects seven drugs of abuse in urine. A urine sample is placed in contact with lyophilized reagents, the reaction mixture is allowed to come to equilibrium (10 min), and then the whole mixture is applied to a solid phase that contains various immobilized antibodies in discrete drug-class-specific zones. After a washing step, the operator visually examines each zone for the presence of a red bar. The method incorporates present threshold concentrations that are independent for each drug. In the absence of drug or in the presence of drug in quantities less than the threshold concentration, no colored bar is visible. Samples containing drug(s) at or above the threshold concentration cause a red bar to appear for the appropriate drug(s). Positive and negative procedural control zones are incorporated into each determination. The performance of the assay methodology matches that of instrumented immunoassay systems.


The following articles in journals at HighWire Press have cited this article:


Home page