Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 38: 1847-1852, 1992;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Evenson, M. A.
Right arrow Articles by Wiktorowicz, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Evenson, M. A.
Right arrow Articles by Wiktorowicz, J. E.

Clinical Chemistry, Vol 38, 1847-1852, Copyright © 1992 by American Association for Clinical Chemistry

Automated capillary electrophoresis applied to therapeutic drug monitoring

MA Evenson and JE Wiktorowicz
Department of Medicine, University of Wisconsin, Madison 53706.

Chromatographic separations in conjunction with physical chemical detection methods can provide extremely accurate and highly precise measurements of drugs in biological matrices. Immunochemical methods for drug analyses, on the other hand, although usually fully automated, often lack accuracy, may be subject to matrix interference effects, and frequently exhibit nonlinearities that contribute to suboptimal analytical results. Automated capillary electrophoresis (CE) promises the high accuracy and precision of physical methods with no operator intervention once the sample is loaded into the sample cup. A clean-up step is necessary for the analysis of drugs in biological matrices, but that could also be fully automated. Reagent costs per test with CE approach zero, because of the use of extremely small volumes of buffers, standards, and controls. We present data supporting CE as an alternative separation strategy for 28 commonly used therapeutic drugs. These can be resolved in less than 16 min with an optimized micelle- based buffer system.