Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 2063-2069, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smith, J.
Right arrow Articles by Osikowicz, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smith, J.
Right arrow Articles by Osikowicz, G.

Clinical Chemistry, Vol 39, 2063-2069, Copyright © 1993 by American Association for Clinical Chemistry

Abbott AxSYM random and continuous access immunoassay system for improved workflow in the clinical laboratory

J Smith and G Osikowicz
Abbott Laboratories, North Chicago, IL 60064.

We describe a new clinical laboratory instrument, the Abbott AxSYM, which provides random- and continuous-access testing for immunoassays, 20 onboard reagents, primary tube sampling, and a throughput of 80 to 120 tests per hour. The AxSYM incorporates three separate analytical technologies for processing immunoassays: microparticle enzyme immunoassay, fluorescence polarization immunoassay, and a novel technology known as ion-capture immunoassay. The system incorporates both common and technology-specific subsystems controlled by a real- time software scheduling processor. Tests can be processed in one- or two-step sandwich or competitive formats, with variable pipetting steps, incubation periods, optical read formats, and wash sequences. Menu capabilities include tests for hepatitis, retrovirus, tumor markers, fertility markers, thyroid functions, and therapeutic drugs. The time to first result is approximately 15-25 min for most routine assays and < or = 15 min for stat assays (i.e., creatine kinase MB isoenzyme, human chorionic gonadotropin beta subunit, and therapeutic drugs). AxSYM assay performance for 23 assays was comparable with that of the Abbott IMx and TDx analyzers; specimen correlation data had correlation coefficients ranging from 0.97 to 0.99 and slopes ranging from 0.99 to 1.10. Within-run imprecision (CV) was 1.5% to 11.4%, with most assays (19 of 23) demonstrating CVs < or = 8.0%.


The following articles in journals at HighWire Press have cited this article:


Home page
CVIHome page
W. Dimech, L. Panagiotopoulos, J. Marler, N. Laven, S. Leeson, and E. M. Dax
Evaluation of Three Immunoassays Used for Detection of Anti-Rubella Virus Immunoglobulin M Antibodies
Clin. Vaccine Immunol., September 1, 2005; 12(9): 1104 - 1108.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
G. T. Maine, R. Stricker, M. Schuler, J. Spesard, S. Brojanac, B. Iriarte, K. Herwig, T. Gramins, B. Combs, J. Wise, et al.
Development and Clinical Evaluation of a Recombinant-Antigen-Based Cytomegalovirus Immunoglobulin M Automated Immunoassay Using the Abbott AxSYM Analyzer
J. Clin. Microbiol., April 1, 2000; 38(4): 1476 - 1481.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
H. A. Hendriks, W. Kortlandt, and W. M. Verweij
Standardized Comparison of Processing Capacity and Efficiency of Five New-Generation Immunoassay Analyzers
Clin. Chem., January 1, 2000; 46(1): 105 - 111.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
S. Friedler, A. Raziel, M. Schachter, D. Strassburger, I. Bukovsky, and R. Ron-El
Luteal support with micronized progesterone following in-vitro fertilization using a down-regulation protocol with gonadotrophin-releasing hormone agonist: a comparative study between vaginal and oral administration
Hum. Reprod., August 1, 1999; 14(8): 1944 - 1948.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. H. Wilson, J. Yu, A. Karian, J. Kozlowski, and S. O'Reilly
Development and Multisite Evaluation of an Automated Assay for B12 on the Abbott AxSYM Analyzer
Clin. Chem., March 1, 1999; 45(3): 428 - 429.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
D. H. Wilson, W. Groskopf, S. Hsu, D. Caplan, T. Langner, M. Baumann, D. DeManno, G. Williams, D. Payette, C. Dagel, et al.
Rapid, automated assay for progesterone on the Abbott AxSYM(TM) analyzer
Clin. Chem., January 1, 1998; 44(1): 86 - 91.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.