Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 2070-2076, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gogstad, G. O.
Right arrow Articles by Borch, S. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gogstad, G. O.
Right arrow Articles by Borch, S. M.

Clinical Chemistry, Vol 39, 2070-2076, Copyright © 1993 by American Association for Clinical Chemistry

Assay of D-dimer based on immunofiltration and staining with gold colloids

GO Gogstad, S Dale, F Brosstad, O Brandsnes, J Holtlund, E Mork, E Gartner and SM Borch
Diagnostica R&D, Nycomed Pharma AS, Oslo, Norway.

In this immunofiltration assay of D-dimer in plasma samples, the antigens are captured by a monoclonal antibody on a porous membrane, and labeled with the same antibody conjugated to gold colloids. The assay time is < 2 min, and a color of intensity proportional to the concentration of D-dimer is left on the membrane. The reference range (mean +/- 2 SD) was 0.336 +/- 0.133 mg/L (n = 69). Linearity was found up to 10 mg/L. Comparison with ELISA results (x) for 198 patients' samples demonstrated a linear regression equation of y = 0.99(+/- 0.05)x + 0.68(+/- 0.07) and a mean square error of 0.503. Comparison of visual reading of the color signal (y) vs reflectometric measurements (x) for 220 patients' samples demonstrated a linear regression equation of y = 2.5(+/- 0.06)x -0.22(+/- 0.04) and a mean square error of 0.095. Bilirubin, hemoglobin, fibrinogen, soluble fibrin, and fibrinogen degradation products and freezing/thawing of samples did not interfere. Some interference from rheumatoid factor, heparin, and the presence of cells or large lipid particles was seen. The variance (CV) was 8-12% within run, 10-18% between runs, and 13-20% between persons. The new assay constitutes a rapid and reliable analytical tool combining simplicity equivalent to that of latex tests with analytical information approaching that of ELISA.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.