Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 2522-2526, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wasowicz, W.
Right arrow Articles by Peretz, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wasowicz, W.
Right arrow Articles by Peretz, A.

Clinical Chemistry, Vol 39, 2522-2526, Copyright © 1993 by American Association for Clinical Chemistry

Optimized steps in fluorometric determination of thiobarbituric acid- reactive substances in serum: importance of extraction pH and influence of sample preservation and storage

W Wasowicz, J Neve and A Peretz
Laboratory of Pharmaceutical Chemistry, Free University of Brussels, Belgium.

A simple, reliable, and reproducible fluorometric method for measuring thiobarbituric acid-reactive substances (TBARS) in serum is proposed, based on the reaction between malondialdehyde (MDA) and thiobarbituric acid. Formation of TBARS was complete at pH 2.4-2.6, but extraction with n-butanol proved complete only at lower pH, i.e., 1.6-1.7. Analytical recoveries of MDA added to serum were 94%-101%; within- and between-run CVs were 2.4-3.6% and 4.6-5.5%; and the detection limit for TBARS in serum was 0.10 mumol/L. Optimized conditions included: (a) collection of either serum or heparinized plasma, (b) preservation from in vitro autoxidation by glutathione and EDTA, and (c) storage at -20 degrees C up to 35 days. The mean (+/- SD) TBARS concentration in 47 healthy adults was 1.01 (0.21) mumol/L; no sex-related difference was observed. Higher concentrations were measured in patients with renal insufficiency undergoing hemodialysis and in patients with insulin- dependent diabetes, chronic pancreatitis, or liver cirrhosis.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.