Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 271-277, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Warnick, G. R.
Right arrow Articles by Riesen, W. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Warnick, G. R.
Right arrow Articles by Riesen, W. F.

Clinical Chemistry, Vol 39, 271-277, Copyright © 1993 by American Association for Clinical Chemistry

Multicenter evaluation of Reflotron direct dry-chemistry assay of high- density lipoprotein cholesterol in venous and fingerstick specimens

GR Warnick, GJ Boerma, G Assmann, AT Endler, G Gerique, AM Gotto, MS Graziani, U Lippi, W Patsch and WF Riesen
Pacific Biometrics, Inc., Seattle, WA 98109.

The Reflotron HDL Cholesterol test (Boehringer Mannheim GmbH) directly separates and analyzes high-density lipoprotein (HDL) cholesterol in plasma collected with EDTA in an integrated dry-reagent system suitable for alternative site testing of lipoproteins. We describe a multicenter evaluation of this test by two US and six European laboratories experienced in lipid analysis. Each laboratory compared the Reflotron with the same conventional wet-chemistry method, Boehringer phosphotungstate-Mg2+ precipitation with enzymatic cholesterol assay. Imprecision was within accepted guidelines, with CVs of < or = 8% for fresh and frozen plasmas (median CV 1.7-3.9%) and for lyophilized sera (median CV 3.8-4.7%), similar to those of the conventional method. Results of linear-regression analysis were as follows: Reflotron HDL Cholesterol = 1.03 conventional - 3.9 mg/L, r = 0.987. The Reflotron results were somewhat low in the two US laboratories, demonstrating the need for general standardization of methods for measuring HDL cholesterol. Results from capillary fingerstick plasma agreed well with those from venous-derived plasma; capillary = 1.04 venous + 4.5 mg/L, r = 0.967. The system is relatively insensitive to interference from hemoglobin (< or = 0.75 g/L), ascorbic acid (< or = 0.3 g/L), bilirubin (< or = 50 mg/L), cholesterol (< or = 3.5 g/L), and triglycerides (< or = 4 g/L). The relative ease of operation and the rapid availability of results (within 90 s for plasma collected in EDTA) make the method appropriate for use by well-trained, but not necessarily technical, operators in the physician's office or other alternative sites.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
J. H. Stein, C. M. Carlsson, K. Papcke-Benson, J. A. Einerson, P. E. McBride, and D. A. Wiebe
Inaccuracy of Lipid Measurements with the Portable Cholestech L{middle dot}D{middle dot}X Analyzer in Patients with Hypercholesterolemia
Clin. Chem., February 1, 2002; 48(2): 284 - 290.
[Abstract] [Full Text] [PDF]