Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 304-308, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Panteghini, M.
Right arrow Articles by Bonora, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Panteghini, M.
Right arrow Articles by Bonora, R.

Clinical Chemistry, Vol 39, 304-308, Copyright © 1993 by American Association for Clinical Chemistry

Clinical and analytical evaluation of a continuous enzymatic method for measuring pancreatic lipase activity

M Panteghini, F Pagani and R Bonora
Laboratorio Analisi Chimico-Cliniche, Spedali Civili, Brescia, Italy.

We report the evaluation of a new commercial kit for the determination of pancreatic lipase activity. The kit is based on the use of a 1,2- diglyceride as substrate and a specific monoglyceride lipase. The detection step is the continuous colorimetric measurement of hydrogen peroxide produced from glycerol by glycerol kinase, glycerol-3- phosphate oxidase, and peroxidase reactions. The procedure appears to be precise (between-day CV < 9%) and the results show good correlation with those obtained by alternative procedures (vs turbidimetry, r = 0.965; vs ultraviolet absorbance-enzymatic method, r = 0.995; vs Ektachem, r = 0.976; vs immunometry, r = 0.970). However, the method is susceptible to interference by increased concentrations (> 4.5 mmol/L) of serum triglycerides. We estimated the reference interval for healthy adults to be 8-44 U/L. When we evaluated clinical efficacy by using receiver-operating characteristic curves and the overlap index, no significant differences were found between the commercial kit and a common turbidimetric assay for diagnosing patients with acute pancreatitis; both methods performed satisfactorily.


The following articles in journals at HighWire Press have cited this article:


Home page
J. Lipid Res.Home page
S. Imamura, J. Kobayashi, K. Nakajima, S. Sakasegawa, A. Nohara, T. Noguchi, M. A. Kawashiri, A. Inazu, S. S. Deeb, H. Mabuchi, et al.
A novel method for measuring human lipoprotein lipase and hepatic lipase activities in postheparin plasma
J. Lipid Res., July 1, 2008; 49(7): 1431 - 1437.
[Abstract] [Full Text] [PDF]


Home page
J. Lipid Res.Home page
S. Imamura, J. Kobayashi, S. Sakasegawa, A. Nohara, K. Nakajima, M. Kawashiri, A. Inazu, M. Yamagishi, J. Koizumi, and H. Mabuchi
A novel method for measuring human hepatic lipase activity in postheparin plasma
J. Lipid Res., February 1, 2007; 48(2): 453 - 457.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
G. Cattozzo, C. Franzini, and G. Melzi d'Eril
Commutability of Calibration and Control Materials for Serum Lipase
Clin. Chem., December 1, 2001; 47(12): 2108 - 2113.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the American Association for Clinical Chemistry.