Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 39: 392-399, 1993;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schneede, J.
Right arrow Articles by Ueland, P. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schneede, J.
Right arrow Articles by Ueland, P. M.

Clinical Chemistry, Vol 39, 392-399, Copyright © 1993 by American Association for Clinical Chemistry

Automated assay of methylmalonic acid in serum and urine by derivatization with 1-pyrenyldiazomethane, liquid chromatography, and fluorescence detection

J Schneede and PM Ueland
Department of Pharmacology and Toxicology, University of Bergen, Haukeland Hospital, Norway.

Determination of methylmalonic acid (MMA) in serum has been established as an accurate test for the diagnosis of cobalamin deficiency. We describe here the development and performance of a liquid- chromatographic assay of MMA in blood and urine. The assay is based on our recent finding that one of the carboxylic acid moieties of some short-chain dicarboxylic acids reacts with the fluorogenic reagent 1- pyrenyldiazomethane in an aqueous medium, whereas the other remains underivatized (Anal Chem 1992; 63:315-9). The pH-dependent ionization of the free carboxylic acid group of 1-pyrenylmethyl monoesters permits retention on anion-exchange columns, which are used for solid-phase extraction. The analysis is done with a cyanopropyl column coupled in series with an octadecyldimethylsilyl column. Solid-phase extraction and sample injection are carried out automatically by a Gilson ASPEC sample processor. The assay response varies linearly with MMA concentration in the range 0.1-1000 mumol/L in serum. The within-day and between-day CVs are 2.8-10.9%, and the detection limit of 5 fmol injected (approximately 20 nmol/L in serum) is sufficiently low to determine MMA in serum (mean 0.187 mumol/L, SD 0.084, range 0.044- 0.431, n = 44) and urine from healthy subjects.


The following articles in journals at HighWire Press have cited this article:


Home page
Am. J. Clin. Nutr.Home page
A. L. Bjorke Monsen and P. M. Ueland
Homocysteine and methylmalonic acid in diagnosis and risk assessment from infancy to adolescence
Am. J. Clinical Nutrition, July 1, 2003; 78(1): 7 - 21.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. M. Kushnir, G. Komaromy-Hiller, B. Shushan, F. M. Urry, and W. L. Roberts
Analysis of Dicarboxylic Acids by Tandem Mass Spectrometry. High-Throughput Quantitative Measurement of Methylmalonic Acid in Serum, Plasma, and Urine
Clin. Chem., November 1, 2001; 47(11): 1993 - 2002.
[Abstract] [Full Text] [PDF]